Sanyo PLC-ET30L RS232C Basic - Page 9

Operation Requirements

Page 9 highlights

PLC_ET30L Basic Serial Command Functional Specifications 6.4 Operation Requirements In the following status of projector, Available Functional Execution Commands are limited. Projector Status Standby Mode Countdown in process Available Functional Execution Commands C00: POWER ON C00: POWER ON Countdown is terminated C01: POWER OFF C02: POWER OFF Countdown is terminated C46: ZOOM C47: ZOOM + C4A: FOCUS C4B: FOCUS + C5D: LENS SHIFT UP C5E: LENS SHIFT DOWN C5F:LENS SHIFT LEFT C60:LENS SHIFT RIGHT Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal Temperature Status When ZOOM+/-, FOCUS +/-, LENS SHIFTUP/ DOWN/LEFT/RIGHT are executed during Countdown is in process, POINTER UP/ DOWN(C3C/C3D) become effective, and ZOOM/FOCUS/LENS SHIFT become enable to control by POINTER UP/DOWN. NONE (No Execution) NONE (No Execution) NONE (No Execution) Abnormal Power Status Power-Save Cooling Down in process Power Save Status Cooling Down in process after OFF operation due to Lamp Failure NONE (No Execution) NONE (No Execution) C00: POWER ON C01: POWER OFF NONE (No Execution) Note) in above status, the projector returns [ACK] [CR] even if it receives the other command. 9/24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

PLC_ET30L Basic Serial Command Functional Specifications
9/24
6.4 Operation Requirements
In the following status of projector, Available Functional Execution Commands are limited.
Projector Status
Available Functional Execution Commands
Standby Mode
C00: POWER ON
Countdown in process
C00: POWER ON
Countdown is terminated
C01: POWER OFF
C02: POWER OFF
Countdown is terminated
C46: ZOOM -
C47: ZOOM +
C4A: FOCUS -
C4B: FOCUS +
C5D: LENS SHIFT UP
C5E: LENS SHIFT DOWN
C5F:LENS SHIFT LEFT
C60:LENS SHIFT RIGHT
When ZOOM+/-, FOCUS +/-, LENS SHIFTUP/
DOWN/LEFT/RIGHT are executed during Countdown
is in process, POINTER UP/ DOWN(C3C/C3D)
become effective, and ZOOM/FOCUS/LENS SHIFT
become enable to control by POINTER UP/DOWN.
Cooling Down in process
NONE (No Execution)
Cooling
Down
due
to
Abnormal
Temperature
NONE (No Execution)
Abnormal Temperature Status
NONE (No Execution)
Abnormal Power Status
NONE (No Execution)
Power-Save Cooling Down in process
NONE (No Execution)
Power Save Status
C00: POWER ON
C01: POWER OFF
Cooling Down in process after OFF
operation due to Lamp Failure
NONE (No Execution)
Note) in above status, the projector returns
[ACK] [CR]
even if it receives the other command
.