Examples of connection The gateway (Router) installed in the network Connecting the projector (PJ01) to the control computer (PC05) via the gateway. Theater Computer Name IP Address Subnet Mask Default Gateway DNS : PC205 : 192.168.200.5 : 255.255.255.0 : 192.168.200.1 : 192.168.201.1 Projector Name: PJ01 IP Address : 192.168.200.15 Subnet Mask : 255.255.255.0 Default Gateway : 192.168.200.1 DNS : 192.168.201.1 Network Group: 192.168.200.0 To another network Office Hub Hub Gateway (Router) IP Address : 192.168.200.1 IP Address : 192.168.100.1 IP Address : 192.168.10.1 Hub ENGLISH Computer Name: PC05 IP Address : 192.168.10.5 Subnet Mask : 255.255.255.0 Default Gateway : 192.168.10.1 DNS : 192.168.201.1 Computer Name IP Address Subnet Mask Default Gateway DNS : PC10 : 192.168.10.10 : 255.255.255.0 : 192.168.10.1 : 192.168.201.1 Computer Name IP Address Subnet Mask Default Gateway DNS : PC51 : 192.168.10.51 : 255.255.255.0 : 192.168.10.1 : 192.168.201.1 Network Group: 192.168.10.0 Computer Name IP Address Subnet Mask Default Gateway DNS : PC61 : 192.168.10.61 : 255.255.255.0 : 192.168.10.1 : 192.168.201.1 49