Sanyo PLC-XU4000 Owner's Manual - Page 52

Standby mode, Network, Count up

Page 52 highlights

Setting Standby mode This function is available when operating the projector via network. Eco Select Eco when you do not use the projector via network. The projector's network function will stop when turning off the projector. Network..... Supply the power to the network function even after turning off the projector. You can turn on/ off the projector via network, modify network environment, and receive an e-mail about projector status while the projector is powered off. Refer to the owner's manual of "Network Set-up and Operation".  Note: • Factory default is Network. • When selecting Network, the cooling fans may be running depending on the temperature inside the projector even if the projector is turned off. P-timer This function allows you to change the setting of the P-timer and execute it. Select one of the following options: Count up... The P-timer display 000:00 appears on the screen and the count starts (000:00-180:00) Count down.. The time set in the Timer setting appears on the screen and the countdown starts. Timer......... Use the Point ▲▼ buttons to set the Timer (1-180 Min). Timer is available in Count down only. Factory default velue is 10 Min. Start........... It executes the count up or count down function. Press the SELECT button at Start and the indication changes into Stop. To stop Count up or Count down, press the SELECT button at Stop on the screen menu, then the indication changes into Restart. Press the SELECT button at Restart to resume Count up or Count down. Reset......... Reset the P-timer values. Press the SELECT button at Reset to return to the following value; Count up ... "000:00" Count down ... Timer that you set Exit To exit the P-timer operation. 52 X: disabled O: enabled Serial command Network Monitor Out Audio Out Direct on *1 *2 *1 When Eco is selected, it is only possible to turn on the projector while using the RS-232C serial port. *2 When switch the Standby MIC out function On and in Standby mode status, only MIC volume can be output. P-timer 0 P-timer display Stop or Cancel the P-timer via Remote Control To stop the P-timer function, press the P-TIMER button. To cancel the P-timer, press and hold the P-TIMER button for a few seconds.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

52
Standby mode
This function is available when operating the projector via
network.
Eco
............
Select
Eco
when you do not use the projector
via network. The projector’s network function
will stop when turning off the projector.
Network
....
Supply the power to the network function even
after turning off the projector. You can turn on/
off the projector via network, modify network
environment, and receive an e-mail about
projector status while the projector is powered
off.
Refer to the owner’s manual of “Network Set-up and
Operation”.
Note:
• Factory default is
Network
.
When selecting
Network
, the cooling fans may be
running
depending on the temperature inside the projector even if
the projector is turned off.
Setting
X: disabled
O: enabled
*1 When Eco is selected, it is only possible to
turn on the projector while using the
RS-232C serial port.
*2 When switch the Standby MIC out function
On and in Standby mode status, only MIC
volume can be output.
Monitor Out
Audio Out
Direct on
Serial command
Network
*1
*2
This function allows you to change the setting of the
P-timer and execute it.
Select one of the following options:
Count up
... The P-timer display
000:00
appears on
the screen and the count starts
(000:00–180:00)
Count down
.. The time set in the Timer setting appears
on the screen and the countdown starts.
Timer
.........
Use the Point ▲▼ buttons to set the
Timer
(1–180 Min)° Timer
is available in
Count down only. Factory default velue is
10 Min
.
Start
..........
It executes the count up or count down
function. Press the SELECT button at
Start
and the indication changes into
Stop
. To stop
Count up
or
Count down
,
press the SELECT button at
Stop
on
the screen menu, then the indication
changes into
Restart
. Press the SELECT
button at
Restart
to resume
Count up
or
Count down
.
Reset
.........
Reset the P-timer values.
Press the SELECT button at
Reset
to
return to the following value;
Count up
... "000:00"
Count down
... Timer that you set
Exit
............
To exit the P-timer operation.
P-timer
P-timer
P-timer display
0
Stop or Cancel the P-timer via Remote Control
To stop the P-timer function, press the P-TIMER
button.
To cancel the P-timer, press and hold the P-TIMER
button for a few seconds.