Sanyo PLC-XU4000 Owner's Manual - Page 61

Replacing the Filters, Resetting the Filter Counter, environments may cause poor image quality° - - lcd projector

Page 61 highlights

Maintenance and Cleaning Replacing the Filters Filter prevents dust from accumulating on the optical elements inside the projector. Should the filter become clogged with dust particles, it will reduce cooling fans' effectiveness and may result in internal heat buildup and adversely affect the life of the projector. If a "Filter warning" icon appears on the screen, replace the filters immediately. Replace the filters by following the steps below. 1 Turn off the projector and unplug the AC power cord from the AC outlet. 2 Turn over the projector and pull out the filter cover (bottom); pull up the handle and take out the whole filter (bottom.) Press up the latches and pull out the filter cover (side); pull out the handle and take out the side filter. 3 Put new filters back into the position. Make sure that the filters are fully inserted to the projector. 4 Connect the AC power cord to the projector and turn on the projector. CAUTION -Do not operate the projector with the filters removed. Dust may accumulate on the optical elements degrading picture quality. -Do not put anything into the air vents. Doing so may result in malfunction of the projector. -Do not wash the filters with water or any other liquid matter. Otherwise the filters may be damaged.  Filter cover (bottom) Handle (pull up) Filter cover (side)  Latches (press up) Filter counter Handle (pull out) RECOMMENDATION We recommend avoiding dusty/smoky environments when you operate the projector. Usage in these environments may cause poor image quality. When using the projector under dusty or smoky conditions, dust may accumulate on a lens, LCD panels, or optical elements inside the projector degrading the quality of a projected image. When the symptoms above are noticed, contact your authorized dealer or service center for proper cleaning. Resetting the Filter Counter Be sure to reset the Filter counter after replacing the filters. 1 Press the MENU button to display the On-Screen Menu. Use the Point▲▼ buttons to select the Setting Menu and then press the Point ► or the SELECT button. 2 Use the Point ▲▼ buttons select Filter counter and then press the Point ► or the SELECT button. Use the Point ▲▼ buttons to select Filter counter reset and then press the SELECT button. The Filter counter Reset? appears. Select Yes to continue. 3 Another confirmation dialog box appears, select Yes to reset the Filter counter. The Filter counter Reset? appears. Select Yes, then another confirmation box appears. Select Yes again to reset the Filter counter. 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

61
Turn off the projector and unplug the AC power cord
from the AC outlet.
Turn over the projector and pull out the filter cover
(bottom); pull up the handle and take out the whole
filter (bottom.)
Press up the latches and pull out the filter cover (side);
pull out the handle and take out the side filter.
1
2
Filter prevents dust from accumulating on the optical elements inside the projector. Should the filter become
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup
and adversely affect the life of the projector. If a “Filter warning” icon appears on the screen, replace the filters
immediately. Replace the filters by following the steps below.
Put new filters back into the position. Make sure that
the filters are fully inserted to the projector.
3
CAUTION
–Do not operate the projector with the filters
removed. Dust may accumulate on the optical
elements degrading picture quality.
–Do not put anything into the air vents. Doing so
may result in malfunction of the projector.
–Do not wash the filters with water or any other
liquid matter. Otherwise the filters may be
damaged.
RECOMMENDATION
We recommend avoiding dusty/smoky environments
when you operate the projector° Usage in these
environments may cause poor image quality°
When using the projector under dusty or smoky conditions,
dust may accumulate on a lens, LCD panels, or optical
elements inside the projector degrading the quality of a
projected image. When the symptoms above are noticed,
contact your authorized dealer or service center for proper
cleaning.
Be sure to reset the Filter counter after replacing the filters.
Press the MENU button to display the On-Screen Menu.
Use the Point
▲▼
buttons to select the
Setting
Menu
and then press the Point
or the SELECT button.
Use the Point
▲▼
buttons select Filter counter and
then press the Point
or
the SELECT button. Use the
Point
▲▼
buttons to select
Filter counter reset
and
then press the SELECT button. The
Filter counter
Reset?
appears. Select
Yes
to continue.
1
2
Resetting the Filter Counter
Filter counter
The
Filter counter
Reset?
appears.
Select
Yes
, then
another confirmation
box appears.
Select
Yes
again
to reset the Filter
counter.
Another confirmation dialog box appears, select
Yes
to
reset the Filter counter.
3
Filter cover (bottom)
Replacing the Filters
Maintenance and Cleaning
Filter cover (side)
Connect the AC power cord to the projector and turn
on the projector.
Latches (press up)
Handle (pull out)
4
Handle (pull up)