Seagate Enterprise Capacity 3.5 HDD/Constellation ES Constellation ES (.1) SA - Page 38

Identify Device command, Description, Value

Page 38 highlights

6.3.1 Identify Device command The Identify Device command (command code ECH) transfers information about the drive to the host following power up. The data is organized as a single 512-byte block of data, whose contents are shown in Table 9 on page 31. All reserved bits or words should be set to zero. Parameters listed with an "x" are drive-specific or vary with the state of the drive. see Section 2.0 on page 4for default parameter settings. The following commands contain drive-specific features that may not be included in the Serial ATA specification. Word 0 1 2 3 4 5 6 7-9 10-19 20 21 22 23-26 27-46 47 48 49 50 51 52 53 54 55 56 57-58 59 60-61 62 63 64 65 Description Configuration information: • Bit 15: 0 = ATA; 1 = ATAPI • Bit 7: removable media • Bit 6: removable controller • Bit 0: reserved Number of logical cylinders ATA-reserved Number of logical heads Retired Retired Number of logical sectors per logical track: 63 Retired Serial number: (20 ASCII characters, 0000H = none) Retired Retired Obsolete Firmware revision (8 ASCII character string, padded with blanks to end of string) Drive model number: (40 ASCII characters, padded with blanks to end of string) (Bits 7-0) Maximum sectors per interrupt on Read multiple and Write multiple (16) Reserved Standard Standby timer, IORDY supported and may be disabled ATA-reserved PIO data-transfer cycle timing mode Retired Words 54-58, 64-70 and 88 are valid Number of current logical cylinders Number of current logical heads Number of current logical sectors per logical track Current capacity in sectors Number of sectors transferred during a Read Multiple or Write Multiple command Total number of user-addressable LBA sectors available (see Section 2.2 for related information) *Note: The maximum value allowed in this field is: 0FFFFFFFh (268,435,455 sectors, 137GB). Drives with capacities over 137GB will have 0FFFFFFFh in this field and the actual number of user-addressable LBAs specified in words 100-103. This is required for drives that support the 48-bit addressing feature. Retired Multiword DMA active and modes supported (see note following this table) Advanced PIO modes supported (modes 3 and 4 supported) Minimum multiword DMA transfer cycle time per word (120 ns) Value 0C5AH 16,383 0000H 16 0000H 0000H 003FH 0000H ASCII 0000H 0400H 0000H x.xx 8010H 0000H 2F00H 0000H 0200H 0200H 0007H xxxxH xxxxH xxxxH xxxxH xxxxH 0FFFFFFFh* 0000H xx07H 0003H 0078H CONSTELLATION ES SERIAL ATA PRODUCT MANUAL, REV. F 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

C
ONSTELLATION
ES S
ERIAL
ATA P
RODUCT
M
ANUAL
, R
EV
. F
33
6.3.1
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following power up. The data is
organized as a single 512-byte block of data, whose contents are shown in Table 9 on page
31. All reserved bits or words should be set to
zero. Parameters listed with an “x” are drive-specific or vary with the state of the drive. see Section 2.0 on page 4for default parameter
settings.
The following commands contain drive-specific features that may not be included in the Serial ATA specification.
Word
Description
Value
0
Configuration information:
• Bit 15: 0 = ATA; 1 = ATAPI
• Bit 7: removable media
• Bit 6: removable controller
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
= none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision
(8 ASCII character string, padded with blanks to end of string)
x.xx
27–46
Drive model number:
(40 ASCII characters, padded with blanks to end of string)
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple and Write
multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be disabled
2F00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle
timing mode
0200
H
52
Retired
0200
H
53
Words 54–58, 64–70 and 88 are valid
0007
H
54
Number of current logical
cylinders
xxxx
H
55
Number of current logical heads
xxxx
H
56
Number of current logical sectors per logical track
xxxx
H
57–58
Current capacity in sectors
xxxx
H
59
Number of sectors transferred during a Read Multiple
or Write Multiple command
xxxx
H
60–61
Total number of user-addressable LBA sectors available
(see Section 2.2 for related information)
*Note: The maximum value allowed in this field is: 0FFFFFFFh
(268,435,455 sectors, 137GB). Drives with capacities over 137GB will
have 0FFFFFFFh in this field and the actual number of user-address-
able LBAs specified in words 100-103. This is required for drives that
support the 48-bit addressing feature.
0FFFFFFFh*
62
Retired
0000
H
63
Multiword DMA active and modes supported
(see note following this table)
xx
07
H
64
Advanced PIO modes supported (modes 3 and 4 supported)
0003
H
65
Minimum multiword DMA transfer cycle time per word (120 ns)
0078
H