Seagate ST120FP0021 Seagate 600 Pro SSD Product Manual - Page 19
Lectromagnetic Immunity
View all Seagate ST120FP0021 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
2.9.6.1 Operating vibration The maximum random vibration levels that the drive may experience while meeting the performance standards specified in this document are specified below. This specification does not cover connection issues that may result from testing at this level. 20-2000 Hz 11.08 Grms 2.9.6.2 Nonoperating vibration The maximum random nonoperating vibration levels that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation are specified below. 20-2000 Hz 11.08 Grms 2.10 ELECTROMAGNETIC IMMUNITY When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Table 8 Radio frequency environments TEST DESCRIPTION PERFORMANCE REFERENCE LEVEL STANDARD Electrostatic discharge Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B EN 61000-4-2: 95 Radiated RF immunity 80 to 1000 MHz, 3 V/m, A 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz EN 61000-4-3: 96 ENV 50204: 95 Electrical fast transient ± 1 kV on AC mains, ± 0.5 kV on external I/O B EN 61000-4-4: 95 Surge immunity ± 1 kV differential, ± 2 kV common, AC mains B EN 61000-4-5: 95 Conducted RF immunity 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A EN 61000-4-6: 97 Voltage dips, interrupts 0% open, 5 seconds 0% short, 5 seconds 40%, 0.10 seconds 70%, 0.01 seconds C EN 61000-4-11: 94 C C B SEAGATE 600 PRO SSD PRODUCT MANUAL, REV. B 15