Seagate ST160LT007 Momentus Thin SATA Product Manual - Page 24
Drive mounting
View all Seagate ST160LT007 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
3.4 Drive mounting You can mount the drive using four screws in the side-mounting holes or four screws in the bottom-mounting holes. See Figure 4 for drive mounting dimensions. Follow these important mounting precautions when mounting the drive: • Allow a minimum clearance of 0.030 inches (0.76 mm) around the entire perimeter of the drive for cooling. • Use only M3 UNC mounting screws. • Do not overtighten the mounting screws. Maximum torque: 4.0 in-lb (0.4519 N-m). • Four (4) threads (0.080 inches, 2.032 mm) minimum screw engagement recommended. • Avoid excessive drive distortion when mounting. Refer to the following specifications for stiffness/deflection information: Top cover stiffness/deflection Operating with no performance degradation, emitted noise, mechanical damage, or hard errors Non-operating with no hard errors 10 mm probe: 1.02kgf or 5 mm probe: 0.92kgf 20 mm probe: 2kgf at any point of top cover 20 mm probe: 15kgf at top cover edges only Measurements shown in Figure 4 are in inches. Figure 4. Mounting dimensions-top, side and end view 18 Momentus Thin Series SATA Product Manual, Rev. B