Seagate ST3300457FC Cheetah 15K.7 FC Product Manual - Page 58

Fibre Channel Process Login Accept, Fibre Channel fabric login

Page 58 highlights

12.1.7 Fibre Channel Process Login Accept Table 12 lists Cheetah 15K.7 FC process login accept payload data. Table 12: Process Login Accept (ACC) payload Bytes 0-15 16-31 02 10 00 14 08 00 21 00 00 00 00 00 00 00 00 00 00 00 00 12 12.1.8 Fibre Channel fabric login Table 13 lists the fabric login payload from the drive. Table 13: Fabric Login (FLOGI) payload Bytes 0-15 04 00 00 00 09 09 00 00 08 00 08 40 00 00 00 00 Common 16-31 00 00 02 F4 2P 00 CC CC CC UI UI UI 02 00 CC CC 32-35 CC UI UI UI 36-47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1 48-51 00 00 00 00 52-63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2 64-67 00 00 00 00 68-79 80 00 00 00 00 00 08 40 00 00 00 00 Class 3 80-83 00 00 00 00 84-95 00 00 00 00 00 00 00 00 00 00 00 00 Reserved 96-99 00 00 00 00 100-111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor - 112-115 00 00 00 00 Version CC Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change). UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name fields. P Port identifier field. 1 FLOGI originated on Port A. 2 FLOGI originated on Port B. 52 Cheetah 15K.7 FC Product Manual, Rev. C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

52
Cheetah 15K.7 FC Product Manual, Rev. C
12.1.7
Fibre Channel Process Login Accept
Table 12 lists Cheetah 15K.7 FC process login accept payload data.
12.1.8
Fibre Channel fabric login
Table 13 lists the fabric login payload from the drive.
Table 12:
Process Login Accept (ACC) payload
Bytes
0-15
02
10
00
14
08
00
21
00
00
00
00
00
00
00
00
00
16-31
00
00
00
12
Table 13:
Fabric Login (FLOGI) payload
Bytes
0-15
04
00
00
00
09
09
00
00
08
00
08
40
00
00
00
00
Common
16-31
00
00
02
F4
2P
00
CC
CC
CC
UI
UI
UI
02
00
CC
CC
32-35
CC
UI
UI
UI
36-47
00
00
00
00
00
00
00
00
00
00
00
00
Class 1
48-51
00
00
00
00
52-63
00
00
00
00
00
00
00
00
00
00
00
00
Class 2
64-67
00
00
00
00
68-79
80
00
00
00
00
00
08
40
00
00
00
00
Class 3
80-83
00
00
00
00
84-95
00
00
00
00
00
00
00
00
00
00
00
00
Reserved
96-99
00
00
00
00
100-111
00
00
00
00
00
00
00
00
00
00
00
00
Vendor -
112-115
00
00
00
00
Version
CC
Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change).
UI
Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name
fields.
P
Port identifier field.
1
FLOGI originated on Port A.
2
FLOGI originated on Port B.