Seagate ST3300457FC Cheetah 15K.7 SAS Product Manual - Page 38

Vibration

Page 38 highlights

Z Y X X Z Y Figure 8. Recommended mounting 7.4.4.2 Vibration a. Operating-normal The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding 10 - 300 Hz 301- 500 Hz 1.0 G RMS (0 to peak) 0.5 G RMS (0 to peak) Vibration may be applied in the X, Y, or Z axis. b. Operating-abnormal Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding: 15 minutes of duration at major resonant frequency Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available. Operating abnormal translational random flat profile 5 - 500 Hz 10 - 300 Hz 0.75 G (0 to peak) 0.0029 G2/Hz c. Non-operating 32 Cheetah 15K.7 SAS Product Manual, Rev. C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

32
Cheetah 15K.7 SAS Product Manual, Rev. C
Z
Y
X
Z
Y
X
Figure 8.
Recommended mounting
7.4.4.2
Vibration
a. Operating—normal
The drive as installed for normal operation, shall comply with the complete specified performance while
subjected to continuous vibration not exceeding
10 – 300 Hz
1.0 G RMS (0 to peak)
301– 500 Hz
0.5 G RMS (0 to peak)
Vibration may be applied in the X, Y, or Z axis.
b. Operating—abnormal
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic
vibration not exceeding:
15 minutes of duration at major resonant frequency
Vibration occurring at these levels may degrade operational performance during the abnormal vibration
period. Specified operational performance will continue when normal operating vibration levels are
resumed. This assumes system recovery routines are available.
Operating abnormal translational random flat profile
5 – 500 Hz
0.75 G (0 to peak)
10 - 300 Hz
0.0029 G
2
/Hz
c. Non-operating