ADJUSTMENT ITEM ADJUSTMENT POSITION - HIGH VOLTAGE STEP RANGE - CONTROL - PRE-ADJUST REQUIREMENT AFTER ALL ADJUSTMENT FINISHED. CONTENT US 4 CH LION HEAD (MONOSCOPE PATTERN) INPUT CONDITION AC 220V, RF INPUT OUTPUTΩ CRT ANODE VOLTAGE SET THE USER CONTROL TO SHIPMENT SETTING POSITION. PUSH ON Y-MUTE BY R/C CONFIRM THE VOLTAGE OF CRT ANODE BY HIGH VOLTAGE METER AND MAKE SURE THE READING IS AS BELOW. HIGH VOLTAGE BELOW 30kV ADJUSTMENT PROCEDURE ADJUSTMENT ITEM ADJUSTMENT POSITION M01 MS LEVEL ADJUSTMENT STEP RANGE CONTROL I2C BUS CONTROL PRE-ADJUST REQUIREMENT OPTION SET UP, BUS SET UP, VCO ADJ, RF-AGC CONTENT MONORAL SIGNAL (400HZ 100% MODULATION) INPUT CONDITION AC 220V, RF INPUT OUTPUT IC 3001 39 PIN 0~15 1) SET THE SOUND VOLUME CONTROL MORE THAN 1. 2) ADJUST BUS DATA OF M01 UNTIL THE VOLTAGE OF 39 PIN BE- COME AS SPECIFIED BELOW. ADJUSTMENT PROCEDURE 21FL94 23 [CAUTION POINT] USE ELECTROSTATIC HI-VOLTAGE METER AND FOLLOW THE UL/ DHHS STANDARD TO MAKE CORRECTION AND CONTROL. HISTORY SYMBOL REVISED CONTENT, OF REVISION 23-1 [CHECKING SPEC] 490 ± 10mVrms (CHECKING SPEC :490 ± 20mVrms) HISTORY SYMBOL REVISED CONTENT, OF REVISION 23-2