21FL94 24 ADJUSTMENT ITEM ADJUSTMENT POSITION M04, M05 SEPARTION ADJUSTMENT STEP RANGE 0~63 CONTROL I2C BUS CONTROL PRE-ADJUST REQUIREMENT CONTENT INPUT CONDITION OPTION SET UP, BUS SET UP, VCO ADJ, RF-AGC, MS-LEVEL, MTS-VCO, FILTER STEREO SIGNAL SIGNAL 1,: MODULATION 30%, L-CH ONLY, NR-ON, 300Hz SIGNAL 2,: MODULATION 30%, L-CH ONLY, NR-ON, 3kHz RF INPUT OUTPUT IC 3001 39 PIN 1) INPUT SIGNAL 1, ADJUST BUS DATA OF M04 UNTIL THE OF 39 PIN BECOME MINIMUM LEVEL. 2) INPUT SIGNAL 2, ADJUST BUS DATA OF M05 UNTIL THE AC VOLTAGE OF 39 PIN BECOME MINIMUM LEVEL. 3) REPEAT STEP 1) AND 2). SET THE SOUND VOLUME TO MAXIMUM THEN MAKE SURE THE READING FROM THE SPEAKER TERMINAL MUST BE OVER THE SPEC AS SPECIFIED BELOW. ADJUSTMENT PROCEDURE [CHECKING SPEC] OVER 25 dB (CHECKING SPEC : OVER 20 dB) HISTORY SYMBOL REVISED CONTENT, OF REVISION 24-1 24-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

24
24-1
21FL94
1)
INPUT SIGNAL 1, ADJUST BUS DATA OF M04 UNTIL THE OF 39 PIN
BECOME MINIMUM LEVEL.
2)
INPUT SIGNAL 2, ADJUST BUS DATA OF M05 UNTIL THE AC VOLT-
AGE OF 39 PIN BECOME MINIMUM LEVEL.
3)
REPEAT STEP 1) AND 2).
SET THE SOUND VOLUME TO MAXIMUM THEN MAKE SURE THE
READING FROM THE SPEAKER TERMINAL MUST BE OVER THE SPEC
AS SPECIFIED BELOW.
SEPARTION ADJUSTMENT
M04, M05
STEP RANGE
0~63
I
2
C BUS CONTROL
OPTION SET UP, BUS SET UP, VCO ADJ, RF-AGC, MS-LEVEL, MTS-VCO, FILTER
STEREO SIGNAL SIGNAL 1,: MODULATION 30%, L-CH ONLY, NR-ON, 300Hz
SIGNAL 2,: MODULATION 30%, L-CH ONLY, NR-ON, 3kHz
RF INPUT
IC 3001 39 PIN
[CHECKING SPEC]
OVER 25 dB (CHECKING SPEC : OVER 20 dB)
SYMBOL
REVISED CONTENT,
ADJUSTMENT
ITEM
ADJUSTMENT
POSITION
CONTROL
PRE-ADJUST
REQUIREMENT
CONTENT
INPUT
CONDITION
OUTPUT
ADJUSTMENT
PROCEDURE
HISTORY
OF REVISION