Sharp AR-5316 AR-5316 Operation Manual - Page 52
B. Misfeed in the fusing area - toner cartridge
View all Sharp AR-5316 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
TROUBLESHOOTING B. Misfeed in the fusing area 1 Push gently on both ends of the front cover. 4 Lift the fusing unit release levers, to return them to their operating positions. 2 Turn the roller rotating knob in the direction of the arrow. Roller rotating knob 5 Close the front cover and side cover. The misfeed indicator ( ) will go out. 3 Carefully remove the misfed paper. Lower the fusing unit release levers to allow easier removal. Fusing unit release lever Be careful not to tear the misfed paper during removal. Note • When closing the front cover, gently hold both ends. • When closing the side cover, press on the handle. • If the misfeed indicator ( ) does not stop blinking, check for torn pieces of paper in the machine. The fusing unit is hot. Do not touch Warning the fusing unit when removing misfed paper. Doing so may cause a burn or injury. • Do not touch the drum cartridge (green Caution portion) when removing the misfed paper. Doing so may damage the drum and cause smudges on copies. • Be careful about unfixed toner on the misfed paper not to soil your hands or clothes. 50