Check the TE waveform at pin 6 on IC1.,
View all Sharp CD-SW330 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
CD-SW330 (2) Tracking system check. Check the TE waveform at pin 6 on IC1. If the waveform shown in Figure 4 appears and soon after NO DISC appears ? No "Initialization" is possible, but play is not possible ? No "Initialization" is not possible. The tracking servo is not activated. Check the peripheral circuits at pins 6, 7, 10, 98 and 100 on Yes IC1, pins 17, 18, 35 and 36 on IC2 and FFC1. A normal jump operation cannot be completed or the beginning of the track cannot be found. Yes Check the around pin 10 on IC1. Data cannot be read. Check the VCO-PLL (Pins 72, 73, 74, 75, 76 and 78 on IC1) system. (3) Spin system check. Press the OPEN/CLOSE switch without inserting a disc, and then try starting the play operation. TEI 46 IC1 FOO 19 IC1 Figure 4 1. The turntable rotates a little ? (Waveform drawing Figure 5) No 2. The turntable doesn't rotate. The spin driver circuit is OK. Yes Check around pin 13 on IC1, pins 3, 4, 13 and 14 on IC2. 1 9 FOO IC1 6 13 DMO IC1 Figure 5 7 - 3