When the turntable fails to stop., When turntable fails to move.
UPC - 074000410244
View all Sharp CDC2900 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
• When the turntable fails to stop. Is from 5V 2.5V 0V 5 V till 2.5V down pulse (approx. 300 ms) input into the IC701 pin 21 when the turntable is rotating? Yes Is there following voltage input on the IC701 pin 21 in the specific state? When the CD mechanism is moved up: 0V In other states: 4.3V Yes Check IC2 pin26 Q91 and Q93 and the periphery. Yes IC701 defective. CD-C622/C2900 No Check the SWM3 and the wiring from the IC701 pin 21 to the SWM3. Check the MECHA UP SW and the wiring from the IC701 pin No 21 to the MECHA UP SW. • When turntable fails to move. Is there following voltage input on the IC701 pin 21 in the specific state? When the CD mechanism is moved up: 0V In other states: 4.3V Yes Is L output from the IC2 pin 26 during SEC when the disc skip switch is pressed? Yes Is 4V output from the Q91 emitter during operation stated above? Yes Check turntable motor and turntable mechanism. Check the MECHA UP SW and the wiring from the IC701 pin No 21 to the MECHA UP SW. Check the wiring of IC2 pin 26 and Q93 pin 2. No OK IC2 defective. Check Q91, Q93 and the periphery. No - 43 -