Sharp DV-NC70U Service Manual - Page 43

Flow Chart No.13, Flow Chart No.14, Flow Chart No.15, Flow Chart No.16, Flow Chart No.17

Page 43 highlights

DV-NC70U/C DV-NC72U 43 FLOW CHART NO.13 The capstan motor fails to run. NO Is the voltage more than about 2.6V DC given out of pin(29) of IC701? YES NO Is the supply voltage of 5V fed up to pin(3) of AC connector? YES Is the voltage more than 2.6V DC sent in pin(9) of NO AC connector? YES Is approx. 3.5V applied to the pin(5) of NO AC connector? YES Is 29V applied to the pin(2) of AC connector NO normally? YES Replace capstan motor. FLOW CHART NO.14 The drum motor fails to run. Is the voltage more than about 2.6V DC given out NO of pin(30) of IC701? YES NO Is the supply voltage of 5V fed up to pin(3) of AC connector? YES Is the voltage more than about 2.6V applied at NO pin(12) of AC connector? YES Is the supply voltage of 12V fed up to pin(8) of NO AC connector? YES Check or replace drum motor. FLOW CHART NO.15 The drum motor runs only for a few seconds. Is drum PG/FG signal given out of pin(11) of NO AC connector? YES Is drum PG/FG signal given out of pin(65) of NO IC701? YES Is V-H.SW.P pulse given out of pin(23) of IC701? NO Replace IC701. YES Check IC701. Check PC 5V line. Check between the pin(9) of AC connector and all the way up thru to pin(29) of IC701. Check the pin(91) of IC701. Check AT 27V line. Check IC701. Check PC 5V line. Check between pin(30) of IC701 and all the way up to pin(12) of AC connector. Check PC 12V line. Check or replace capstan motor or drum motor. Check line between pin(11) of AC connector and all the way up thru to pin(65) of IC701. Check IC701. FLOW CHART NO.16ɹɹɹɹɹ No head switching pulse. NO Is the drum motor rotating? YES Is the drum PG signal and drum FG signal present on pin(65) of IC701, respectively? YES NO D-FG See FLOW CHART NO.14, 15. Replace IC701. D-PG Are the drum PG/FG signals present on pin(11) of NO AC connector? YES Check or replace capstan motor unit and drum motor unit. About 5Vp-p About 5Vp-p Check line between pin(11) of AC connector and all the way up thru to pin(65) of IC701. FLOW CHART NO.17 Drum servo does not function. Is there 14.3MHz oscillation at pins(37) and (38) of IC701? YES In PB mode Is there drum PG/FG signal at pin(65) of IC701 present? YES NO Is the head switching pulse at pin(23) of IC701 present? YES Is the drum APC output at pin(34) of IC701 and drum AFC output at pin(32) of IC701 present? YES Is the drum control voltage applied to pin(12) of AC connector? YES Replace capstan motor or drum motor. NO Check peripheral circuit of X701. In REC mode YES Is there V-SYNC signal (reference) at pin(50) of IC701? NO Check peripheral circuit of C715, C716 and R708. Check drum PG/FG signal line. NO See FLOW CHART NO.16. NO Replace IC701. NO Is pin(30) of IC701 in high impedance?

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

43
DV-NC70U/C
DV-NC72U
FLOW CHART NO.13
Is the voltage more than about 2.6V DC given out
of pin(29) of IC701?
Check IC701.
Is the supply voltage of 5V fed up to pin(3) of
AC connector?
Check PC 5V line.
Is the voltage more than 2.6V DC sent in pin(9) of
AC connector?
Check between the pin(9) of AC connector and all
the way up thru to pin(29) of IC701.
Replace capstan motor.
NO
NO
NO
YES
YES
YES
Is approx. 3.5V applied to the pin(5) of
AC connector?
Check the pin(91) of IC701.
NO
YES
Is 29V applied to the pin(2) of AC connector
normally?
Check AT 27V line.
NO
YES
The capstan motor fails to run.
FLOW CHART NO.14
Is the voltage more than about 2.6V DC given out
of pin(30) of IC701?
Check IC701.
Is the supply voltage of 5V fed up to pin(3) of
AC connector?
Check PC 5V line.
Is the voltage more than about 2.6V applied at
pin(12) of AC connector?
Check between pin(30) of IC701 and all the way
up to pin(12) of AC connector.
NO
NO
NO
YES
YES
Is the supply voltage of 12V fed up to pin(8) of
AC connector?
Check PC 12V line.
NO
YES
Check or replace drum motor.
YES
The drum motor fails to run.
FLOW CHART NO.15
Is drum PG/FG signal given out of pin(11) of
AC connector?
Check or replace capstan motor or drum motor.
Check line between pin(11) of AC connector and
all the way up thru to pin(65) of IC701.
Is V-H.SW.P pulse given out of pin(23) of IC701?
Check IC701.
Replace IC701.
NO
NO
NO
YES
YES
YES
Is drum PG/FG signal given out of pin(65) of
IC701?
The drum motor runs only for a few seconds.
FLOW CHART NO.16
Is the drum motor rotating?
See FLOW CHART NO.14, 15.
<The drum motor fails to run>
<The drum motor runs only for a few seconds>
Is the drum PG signal and drum FG signal present
on pin(65) of IC701, respectively?
Replace IC701.
Are the drum PG/FG signals present on pin(11) of
AC connector?
Check line between pin(11) of AC connector and
all the way up thru to pin(65) of IC701.
NO
NO
NO
YES
YES
YES
No head switching pulse.
D-FG
About 5Vp-p
D-PG
About 5Vp-p
Check or replace capstan motor unit and
drum motor unit.
FLOW CHART NO.17
Is there 14.3MHz oscillation at pins(37) and (38)
of IC701?
Check peripheral circuit of X701.
Is there drum PG/FG signal at pin(65) of IC701
present?
Is there V-SYNC signal (reference) at pin(50) of IC701?
NO
YES
In PB mode
YES
In REC mode
Is the head switching pulse at pin(23) of IC701
present?
See FLOW CHART NO.16.
<No head switching pulse>
NO
YES
NO
Is the drum APC output at pin(34) of IC701 and
drum AFC output at pin(32) of IC701 present?
Replace IC701.
NO
YES
Is the drum control voltage applied to pin(12) of
AC connector?
Is pin(30) of IC701 in high impedance?
NO
YES
YES
Replace capstan motor or drum motor.
Drum servo does not function.
Check peripheral circuit of C715, C716 and R708.
NO
Check drum PG/FG signal line.