RS-232C Port Specifications

Page 53 highlights

RS-232C Port Specifications PC control A computer can be used to control the projector by connecting an RS-232C cable (null modem, cross type, sold separately) to the projector. (See page 14 for connection.) Communication conditions Set the serial port settings of the computer to match that of the table. Signal format: Conforms to RS-232C standard. Baud rate: 9,600 bps Data length: 8 bits Parity bit: NON Stop bit: 1 bit Flow control: None Basic format Commands from the computer are sent in the following order: command, parameter, and return code. After the projector processes the command from the computer, it sends a response code to the computer. Command format C1 C2 C3 C4 P1 P2 P3 P4 Return code (0DH) Command 4-digits Response code format Normal response Parameter 4-digits O K Return code (0DH) Problem response (communication error or incorrect command) E R R Return code (0DH) When more than one code is being sent, send each command only after the OK response code for the previous command from the projector is verified. • When using the computer control function of the projector, the projector operating status cannot be read to the computer. Therefore, confirm the status by transmitting the display commands for each adjustment menu and checking the status with the On-screen Display. If the projector receives a command other than a menu display command, it will execute the command without displaying the On-screen Display. Commands EXAMPLE • When "BRIGHT" of INPUT 1 IMAGE ADJUSTMENT is set to ‫מ‬10. Computer RABR _‫מ‬1 0 → ← Projector OK CONTROL ITEM POWER SETTING INPUT SWITCHING INPUT CHECK VOLUME ADJUSTMENT KEYSTONE ADJUSTMENT DIGITAL SHIFT COMMAND PARAMETER C1 C2 C3 C4 P1 P2 P3 P4 CONTROL CONTENTS P O W R _ _ _ 0 POWER OFF (STANDBY) P O W R _ _ _ 1 POWER ON I R G B _ _ _ 1 INPUT1 I R G B _ _ _ 2 INPUT2 I V E D _ _ _ 1 INPUT3 (VIDEO) I C H K _ _ _ 0 INPUT CHECK V O L A _ _ * * VOLUME (00 - 60) M U T E _ _ _ 0 MUTE OFF M U T E _ _ _ 1 MUTE ON K EY S * * * * KEYSTONE (‫מ‬127 - ‫ם‬127) L ND S _ * * * DIGITAL SHIFT (‫מ‬96 - ‫ם‬96) CONTROL ITEM COMMAND PARAMETER C1 C2 C3 C4 P1 P2 P3 P4 CONTROL CONTENTS INPUT 1 SIGNAL TYPE I A S I _ _ _ 1 RGB SELECTION I A S I _ _ _ 2 COMPONENT INPUT 1 I/P CONVERSION R A I P _ _ _ 0 INTERLACED R A I P _ _ _ 1 PROGRESSIVE R A C T _ _ * * COLOR TEMPERATURE (‫מ‬3 - ‫ם‬3) R A P I _ * * * CONTRAST (‫מ‬30 - ‫ם‬30) R A B R _ * * * BRIGHT (‫מ‬30 - ‫ם‬30) INPUT 1 IMAGE ADJUSTMENT R A R D _ * * * RED (‫מ‬30 - ‫ם‬30) R A B E _ * * * BLUE (‫מ‬30 - ‫ם‬30) R A C O _ * * * COLOR (‫מ‬30 - ‫ם‬30) R A T I _ * * * TINT (‫מ‬30 - ‫ם‬30) R A R E _ _ _ 0 INPUT 1 DISPLAY R A R E _ _ _ 1 RESET Appendix E-52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

E-52
Appendix
PC control
A computer can be used to control the projector by connecting an RS-232C cable (null modem, cross type, sold
separately) to the projector. (See page 14 for connection.)
Communication conditions
Set the serial port settings of the computer to match that of the table.
Signal format:
Conforms to RS-232C standard.
Baud rate:
9,600 bps
Data length:
8 bits
Parity bit:
NON
Stop bit:
1 bit
Flow control:
None
Basic format
Commands from the computer are sent in the following order: command, parameter, and return code. After the
projector processes the command from the computer, it sends a response code to the computer.
RS-232C Port Specifications
Return code
(
0DH
)
C1
C2
C3
C4
P1
P2
P3
P4
Response code format
Normal response
O
K
Return code
(
0DH
)
Problem response (communication error or incorrect command)
E
R
R
Return code
(
0DH
)
Command 4-digits
Parameter 4-digits
Command format
When more than one code is being sent, send each command only after the OK response code for the previous
command from the projector is verified.
When using the computer control function of the projector, the projector operating status cannot be read to the computer.
Therefore, confirm the status by transmitting the display commands for each adjustment menu and checking the status with
the On-screen Display. If the projector receives a command other than a menu display command, it will execute the com-
mand without displaying the On-screen Display.
Commands
EXAMPLE
When
BRIGHT
of INPUT 1 IMAGE ADJUSTMENT is set to
³
10.
R
A
B
R
1
0
_
³
O
K
Projector
Computer
CONTROL ITEM
COMMAND
C1
P
P
I
I
I
I
V
M
M
O
O
R
R
V
C
O
U
U
W
W
G
G
E
H
L
T
T
R
R
B
B
D
K
A
E
E
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
*
_
_
0
1
1
2
1
0
*
0
1
POWER OFF (STANDBY)
POWER ON
INPUT1
INPUT2
INPUT3 (VIDEO)
INPUT CHECK
VOLUME (00
60)
MUTE OFF
MUTE ON
KEYSTONE
(
³
127
²
127)
C2
C3
C4
P1
P2
P3
P4
PARAMETER
CONTROL
CONTENTS
INPUT SWITCHING
POWER SETTING
KEYSTONE
ADJUSTMENT
DIGITAL
SHIFT
VOLUME
ADJUSTMENT
E
K
Y
S
*
*
*
*
DIGITAL SHIFT
(
³
96
²
96)
N
L
D
S
_
*
*
*
INPUT CHECK
INPUT 1
IMAGE
ADJUSTMENT
INPUT 1
I/P CONVERSION
INPUT 1 SIGNAL TYPE
SELECTION
CONTROL ITEM
COMMAND
C1
I
I
R
R
R
R
R
R
R
R
R
R
R
A
A
A
A
A
A
A
A
A
A
A
A
A
S
S
I
I
C
P
B
R
B
C
T
R
R
I
I
P
P
T
I
R
D
E
O
I
E
E
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
*
*
*
*
*
*
_
_
_
_
_
_
*
*
*
*
*
*
*
_
_
1
2
0
1
*
*
*
*
*
*
*
0
1
RGB
COMPONENT
INTERLACED
PROGRESSIVE
COLOR TEMPERATURE
(
³
3
²
3)
CONTRAST (
³
30
²
30)
BRIGHT (
³
30
²
30)
RED (
³
30
²
30)
BLUE (
³
30
²
30)
COLOR (
³
30
²
30)
TINT (
³
30
²
30)
INPUT 1 DISPLAY
RESET
C2
C3
C4
P1
P2
P3
P4
PARAMETER
CONTROL
CONTENTS