Removing and Installing the Lamp Unit, Lamp Unit - an 100lp
UPC - 074000364820
View all Sharp XV-Z3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Removing and Installing the Lamp Unit Warning! • The lamp unit becomes very hot while the projector is operating. Do not remove the lamp unit from the projector right after use. The lamp and parts around the lamp will be very hot and may cause burns or injury. Optional accessory Lamp unit AN-100LP Info • Make sure that you remove the lamp unit by the handle. Do not touch the glass surface of the lamp unit or the inside of the projector. • To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below. • Do not loosen other screws except for the lamp unit cover and lamp unit. 1 Press SSTANDBY/ON on the projector or aSTANDBY on the remote control to put the projector into standby mode. • Wait until the cooling fan stops. STANDBY/ON button AC socket 2 Disconnect the power cord. • Unplug the power cord from the AC socket. • Leave the lamp until it has fully cooled down (about 1 hour). 3 Remove the lamp unit cover. • Turn the projector over. Loosen the user service screw (1) that secures the lamp unit cover. Remove the lamp unit cover (2). 1 2 User service screw (for lamp unit cover) Appendix 55