Sony CCD TR818 Operating Instructions - Page 52

Troubleshooting, Types of trouble and their solutions

Page 52 highlights

- Troubleshooting - Types of trouble and their solutions If you run into any problem using your camcorder, use the following table to troubleshoot the problem. If the problem persists, disconnect the power source and contact your Sony dealer or local authorized Sony service facility. If "C:ss:ss" appears in the viewfinder or the display window, the self-diagnosis display function has worked. See page 55. In the recording mode Symptom START/STOP does not operate. The power goes off. The image on the viewfinder screen is not clear. The SteadyShot function does not work. (CCD-TR818 only) The autofocusing function does not work. The x indicator flashes in the viewfinder. A vertical band appears when you shoot a subject such as lights or a candle flame against a dark background. Cause and/or Corrective Actions • The POWER switch is set to OFF (CHARGE) or PLAYER. c Set it to CAMERA. (p. 20) • The tape has run out. c Rewind the tape or insert a new one. (p. 19, 27) • The write-protect tab is set to expose the red mark. c Use a new tape or slide the tab. (p. 19) • The tape is stuck to the drum (moisture condensation). c Remove the cassette and leave your camcorder for at least 1 hour to acclimatize. (p. 60) • While being operated in CAMERA mode, your camcorder has been in the standby mode for more than 5 minutes. c Set the POWER switch to OFF (CHARGE) and then to CAMERA again. • The battery pack is dead or nearly dead. c Install a fully charged battery pack. (p. 11, 12) • The viewfinder lens is not adjusted. c Adjust the viewfinder lens. (p. 21) • STEADYSHOT is set to OFF in the menu settings. c Set it to ON. (p. 46) • The SteadyShot function does not work when the wide mode is set to 16:9FULL. • FOCUS is set to MANUAL. c Set it to AUTO. (p. 37) • Shooting conditions are not suitable for autofocus. c Set FOCUS to MANUAL to focus manually. (p. 37) • The video heads may be dirty. c Clean the heads using the Sony V8-25CLD cleaning cassette (optional). (p. 61) • The contrast between the subject and background is too high. This is not a malfunction. A vertical band appears when you shoot a very bright subject. An unknown picture is displayed in the viewfinder. • This is not a malfunction. • If 10 minutes elapse after you set the POWER switch to CAMERA or DEMO MODE is set to ON in the menu settings without a cassette inserted, your camcorder automatically starts the demonstration. c Insert a cassette and the demonstration stops. You can also cancel DEMO MODE. (p. 50) 52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

52
— Troubleshooting —
Types of trouble and their solutions
If you run into any problem using your camcorder, use the following table to
troubleshoot the problem. If the problem persists, disconnect the power source and
contact your Sony dealer or local authorized Sony service facility. If “C:
ss
:
ss
appears in the viewfinder or the display window, the self-diagnosis display function
has worked. See page 55.
In the recording mode
Symptom
Cause and/or Corrective Actions
• The POWER switch is set to OFF (CHARGE) or PLAYER.
c
Set it to CAMERA. (p. 20)
• The tape has run out.
c
Rewind the tape or insert a new one. (p. 19, 27)
• The write-protect tab is set to expose the red mark.
c
Use a new tape or slide the tab. (p. 19)
• The tape is stuck to the drum (moisture condensation).
c
Remove the cassette and leave your camcorder for at
least
1 hour to acclimatize. (p. 60)
• While being operated in CAMERA mode, your camcorder
has been in the standby mode for more than 5 minutes.
c
Set the POWER switch to OFF (CHARGE) and then to
CAMERA again.
• The battery pack is dead or nearly dead.
c
Install a fully charged battery pack. (p. 11, 12)
• The viewfinder lens is not adjusted.
c
Adjust the viewfinder lens. (p. 21)
• STEADYSHOT is set to OFF in the menu settings.
c
Set it to ON. (p. 46)
• The SteadyShot function does not work when the wide
mode is set to 16:9FULL.
• FOCUS is set to MANUAL.
c
Set it to AUTO. (p. 37)
• Shooting conditions are not suitable for autofocus.
c
Set FOCUS to MANUAL to focus manually. (p. 37)
• The video heads may be dirty.
c
Clean the heads using the Sony V8-25CLD cleaning
cassette (optional). (p. 61)
• The contrast between the subject and background is too
high. This is not a malfunction.
• This is not a malfunction.
• If 10 minutes elapse after you set the POWER switch to
CAMERA or DEMO MODE is set to ON in the menu
settings without a cassette inserted, your camcorder
automatically starts the demonstration.
c
Insert a cassette and the demonstration stops.
You can also cancel DEMO MODE. (p. 50)
START/STOP does not operate.
The power goes off.
The image on the viewfinder screen
is not clear.
The autofocusing function does not
work.
The
x
indicator flashes in the
viewfinder.
A vertical band appears when you
shoot a subject such as lights or a
candle flame against a dark
background.
An unknown picture is displayed in
the viewfinder.
A vertical band appears when you
shoot a very bright subject.
The SteadyShot function does not
work.
(CCD-TR818 only)