Sony FCBEX490DP User Manual (FCB-490D_Technical_Manual) - Page 19

Eclipse, Spectral Sensitivity Characteristics, Vibration Specifications

Page 19 highlights

11.13 14.18 Eclipse When designing the housing, refer to the dimensional allowance as shown in the figure below. Basic Functions Vibration Specifications Test Method (Random vibration) • Fix the camera at the four fixation points of the base using M2 screws. • Perform the random vibration test under the following conditions in the X, Y and Z directions for 20 minutes in each direction. • The camera vibration specification is to have no malfunction after this test. Power spectrum density 5 to 50 Hz 4.14 m2/s3 {0.043 G2/Hz} 50 to 100 Hz -36 dB/oct Effective overall value 14.3 m/s2 {1.46 G} Test time 20 minutes 31.2˚ 15.9˚ Spectral Sensitivity Characteristics Use the graph as a reference value. (We can not guaranttee these values.) This data is measured when the IR cut filter is removed and the characteristics of the lens and optical source characteristics are ignored. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

19
Basic Functions
Spectral Sensitivity
Characteristics
Use the graph as a reference value. (We can not
guaranttee these values.)
This data is measured when the IR cut filter is
removed and the characteristics of the lens and optical
source characteristics are ignored.
Vibration
Specifications
Test Method (Random vibration)
• Fix the camera at the four fixation points of the base
using M2 screws.
• Perform the random vibration test under the
following conditions in the X, Y and Z directions for
20 minutes in each direction.
• The camera vibration specification is to have no
malfunction after this test.
Power spectrum density
Effective overall value
Test time
5 to 50 Hz
4.14 m
2
/s
3
{0.043 G
2
/Hz}
50 to 100 Hz
–36 dB/oct
14.3 m/s
2
{1.46 G}
20 minutes
Eclipse
When designing the housing, refer to the dimensional
allowance as shown in the figure below.
31.2˚
11.13
15.9˚
14.18