VISCA Device Setting, Command, For VISCA Network Administration, VISCA Interface Command - camera fcb ix11ap
View all Sony FCBIX11AP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
VISCA Device Setting Command Before starting control of the FCB series camera, be sure to send the Address command and the IF_Clear command using the broadcast function. For VISCA Network Administration ● Address Sets an address of a peripheral device. Use when initializing the network and when receiving the network change message indicated below. ● Network Change Sent from the peripheral device to the controller when a device is removed from or added to the network. The address must be re-set when this message is received. Packet Note Address 88 30 01 FF Always broadcasted. Network Change X0 38 FF X = 9 to F: FCB series camera address + 8 VISCA Interface Command ● IF_Clear Clears the command buffers in the FCB series camera and cancels the command currently being executed. Command Packet Reply Packet Note IF_Clear 8X 01 00 01FF X0 50 FF IF_Clear (broadcast) 88 01 00 01 FF 88 01 00 01 FF X = 1 to 7: FCB series camera address (For inquiry packet) X = 9 to F: FCB series camera address +8 (For reply packet) Command List VISCA Interface and Inquiry ● IF_DeviceTypeInq Returns information on the VISCA interface. Inquiry IF_DeviceTypeInq Inquiry Packet Reply Packet Description 8X 09 00 02 FF Y0 50 GG GG HH GGGG = Vender ID HH JJ JJ KK FF (0020: Sony) HHHH = Model ID 042E=FCB-IX11A 042F=FCB-IX11AP JJJJ = ROM revision KK = Maximum socket # (02) X = 1 to 7: FCB series camera address (For inquiry packet) X = 9 to F: FCB series camera address +8 (For reply packet) 23