Troubleshooting, Power sources, Cassette tapes, Output/Playback, Symptom, Cause/Remedy
UPC - 027242746756
View all Sony HVR-M15AU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
Troubleshooting Chapter 5 Maintenance Power sources Symptom Cause/Remedy The power cannot be turned on. • The AC power cord is disconnected. t Connect the AC power cord. The unit will not operate even if the power has been turned on. • Moisture condensation has occurred (page 69). • The cassette is not inserted straight. t Eject and reinsert it correctly. t Disconnect the power supply and then reconnect it after about 1 minute. If the unit does not operate even after you reconnect the power, use a sharp-tipped ballpoint pen or similar tool to press the RESET button. When you press the RESET button, all settings, including the date, time, and 60i/50i are initialized (page 13). The unit does not operate properly when t Turn off the power and remove the power cord from the AC outlet and then the AC Adaptor is used. reconnect the power cord. Cassette tapes Symptom Cause/Remedy The cassette cannot be inserted. • There is moisture condensation on the head drum (page 69). t With the unit powered on, wait more than one hour. • The cassette is not inserted straight. t Eject and reinsert it correctly. • Another cassette has been loaded already. t Remove the cassette and insert the one you want to load. It takes time to eject the cassette. • This is not a malfunction. t The unit ejects the cassette slowly to protect the tape. While the cassette is being ejected, the q (cassette) indicator blinks. The cassette tape is not ejected when you t Check whether the power supply is connected properly. press the EJECT button. • Moisture condensation has occurred in the unit (page 69). The cassette memory data and title are not • The unit does not support the cassette memory function and therefore such data displayed when using a cassette tape with is not displayed. the cassette memory function. The remaining tape time is not displayed. t To always display the remaining tape time, set [ REMAINING] in the [DISPLAY SET] menu to [ON] (page 53). Output/Playback Symptom Superimposed text data is displayed on the monitor. Cannot playback. Cannot playback in reverse at various speeds. 30p and/or 24p characteristics of the tape are not detected. Cause/Remedy t Change the setting of the DISPLAY OUTPUT switch on the front panel (page 6). You cannot select the type of the text data to be displayed. t If the tape has reached its end, rewind the tape. • The unit cannot play back a tape recorded in HDV format in the reverse direction at various speeds (page 33). • While the tape is fast forwarding or rewinding during playback, a portion of the tape recorded using 30p or 24p system has been detected as that of a 60i system. t To detect the portion as 30p or 24p, search for the part during playback at normal speed. 60 Chapter 5 Maintenance