Sony STR DA2400ES Operating Instructions - Page 49

To set Auto Calibration items, more precisely, Message list after Auto Calibration measurement - preamp

Page 49 highlights

Message list after Auto Calibration measurement Getting Started Error and Explanation warning code Error Code 31 SPEAKERS (OFF/A/B/A+B) is set to off. Set it to others and re-perform the measurement. Error Code 32 None of the speakers were detected. Make sure that the optimizer microphone is connected properly and reperform the measurement. If the optimizer microphone is connected properly but the error code appears, the optimizer microphone cable may be damaged or improperly connected. Error Code 33 • None of the front speakers are connected or only one front speaker is connected. • The optimizer microphone is not connected. • Either the left or right surround speakers is not connected. • Surround back speakers are connected even though surround speakers are not connected. Connect the surround speaker(s) to the SURROUND terminals. • The surround back speaker is connected only to the SPEAKERS SURROUND BACK R terminals. When you connect only one surround back speaker, connect it to the SPEAKERS SURROUND BACK L terminals. Warning 40 The measurement has completed. However, the noise level is high. You may be able to perform the measurement properly if you try it again, even though the measurement cannot be performed in all environments. Try to perform the measurement in a quiet environment. Warning 41 The input from the microphone is too big. • It may be too close the distance between the speaker and the microphone. Retry the measurement after setting apart from each other. • It may be that the volume is too big when you use the receiver as a preamp. Warning 42 The input from the microphone is too big. • It may be too close the distance between the speaker and the microphone. Retry the measurement after setting apart from each other. • It may be that the volume is too big when you use the receiver as a preamp. Warning 43 The distance and position of a subwoofer cannot be detected. This may be caused by noise. Try to perform the measurement in a quiet environment. NO WARNING There is no warning information. •Error Code 31, 32, 33 1 When you press , "RETRY?" appears. 2 Press B/b to select "YES". 3 Press , then follow the instructions from step 1 of "Performing Auto Calibration". When a warning code appears If a warning on the measurement result is present, detailed information is displayed. Press to return to step 1 of "Confirming/saving the measurement results" (page 47). Tip Depending on the position of the subwoofer, the measurement results for polarity may vary. However, there will be no problems even if you continue to use the receiver with that value. To set Auto Calibration items more precisely On the Auto Calibration setting menu, press . • Position You can register three patterns as Position 1, 2, and 3, depending on the seating position, listening environment, and measurement conditions. • Auto Calibration Type You can select this parameter only when you have performed the Auto Calibration and saved the measurement result. For details, see the table on page 48. • Name Input You can rename the position number. For details, refer to "Naming inputs" (page 96). 49US

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140

49
US
Getting Started
•Error Code 31, 32, 33
1
When you press
, “RETRY?” appears.
2
Press
B
/
b
to select “YES”.
3
Press
, then follow the instructions from
step 1 of “Performing Auto Calibration”.
When a warning code appears
If a warning on the measurement result is
present, detailed information is displayed.
Press
to return to step 1 of
“Confirming/saving the measurement
results” (page 47).
Tip
Depending on the position of the subwoofer, the
measurement results for polarity may vary.
However, there will be no problems even if you
continue to use the receiver with that value.
To set Auto Calibration items
more precisely
On the Auto Calibration setting menu,
press
.
• Position
You can register three patterns as Position 1,
2, and 3, depending on the seating position,
listening environment, and measurement
conditions.
Auto Calibration Type
You can select this parameter only when you
have performed the Auto Calibration and
saved the measurement result.
For details, see the table on page 48.
Name Input
You can rename the position number. For
details, refer to “Naming inputs” (page 96).
Message list after Auto Calibration measurement
Error and
warning code
Explanation
Error Code 31
SPEAKERS (OFF/A/B/A+B) is set to off. Set it to others and re-perform the measurement.
Error Code 32
None of the speakers were detected. Make sure that the optimizer microphone is connected
properly and reperform the measurement.
If the optimizer microphone is connected properly but the error code appears, the optimizer
microphone cable may be damaged or improperly connected.
Error Code 33
None of the front speakers are connected or only one front speaker is connected.
The optimizer microphone is not connected.
Either the left or right surround speakers is not connected.
Surround back speakers are connected even though surround speakers are not connected.
Connect the surround speaker(s) to the SURROUND terminals.
The surround back speaker is connected only to the SPEAKERS SURROUND BACK R
terminals. When you connect only one surround back speaker, connect it to the SPEAKERS
SURROUND BACK L terminals.
Warning 40
The measurement has completed. However, the noise level is high. You may be able to
perform the measurement properly if you try it again, even though the measurement cannot
be performed in all environments. Try to perform the measurement in a quiet environment.
Warning 41
The input from the microphone is too big.
It may be too close the distance between the speaker and the microphone. Retry the
measurement after setting apart from each other.
It may be that the volume is too big when you use the receiver as a preamp.
Warning 42
The input from the microphone is too big.
It may be too close the distance between the speaker and the microphone. Retry the
measurement after setting apart from each other.
It may be that the volume is too big when you use the receiver as a preamp.
Warning 43
The distance and position of a subwoofer cannot be detected. This may be caused by noise.
Try to perform the measurement in a quiet environment.
NO WARNING
There is no warning information.