Stihl BGE 71 Product Instruction Manual - Page 15
Switching
View all Stihl BGE 71 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Strain Relief To reduce the risk of disconnection of the power supply cord from the extension cord set during operation: 3 54 Switching On N Make sure you have a secure and firm footing. N Hold the unit in the normal working position. 1 English N Wait about 3 to 5 minutes for the overload circuit breaker to cool down - do not switch on the unit during this period because the cooling down time will otherwise be much longer. N Connect the plug to the power outlet and switch on the unit. If the motor does not start when you switch on, the overload circuit breaker has not cooled down sufficiently. 290BA013 KN 290BA016 KN N Make a loop in the extension cord. N Pass the loop (3) through the opening (4). N Slip the loop over the hook (5) and pull it tight. N Connect the extension cord plug to a properly installed power outlet. BGE 61 N Move the switch (1) to I. BGE 71 N Move the switch (1) to I or II. I = half power II = full power Overload Circuit Breaker The overload circuit breaker cuts off the power supply to the unit in case of mechanical overload. This can occur, for example, if the blower wheel is blocked. If the overload circuit breaker has cut off the power supply: N Switch off the unit and disconnect the plug from the power outlet. N Determine why the overload circuit breaker has tripped and rectify the problem. BGE 61, BGE 71 13