Sub-Zero 700BCI Sub-Zero Design Guide - Page 30

Built-In Refrigeration, Dual Installation

Page 30 highlights

Built-In Refrigeration 30 Dual installation-standard application. Dual Installation Panel Requirements MAX WEIGHT PER PANEL BI-36R, BI-36RG and BI-36F All Other Models Dual Wide Grille Panel MIN PANEL THICKNESS Framed Panels Overlay and Flush Inset Panels Dual Installation STANDARD APPLICATION Two overlay or stainless steel units may be placed side by side in a dual installation. Some standard applications will require a dual installation kit, available through your authorized Sub-Zero dealer. If you are installing two units side by side in a flush inset application, refer to page 32. A custom filler strip can be used between two units in a framed, overlay or stainless steel design application. It is recommended that the filler strip be at least 2" (51) wide to prevent condensation between the units. Be sure to add the filler strip width to your rough opening width. Refer to the full-scale template on page 42. Dual installations without a filler strip can only be accomplished using two units with opposite hinges as shown in illustration A below. The dual installations shown in illustrations B and C require a filler strip. IMPORTANT NOTE: For the application shown in illustration A, a dual installation accessory kit is required. Refer to page 36 for information on dual installation kits. 75 lbs (34 kg) 50 lbs (23 kg) 26 lbs (12 kg) 1/4" (6) 5/8" (16) WITHOUT FILLER STRIP FILLER STRIP REQUIRED FILLER STRIP REQUIRED Illus. A Illus. B Illus. C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

Built-In Refrigeration
30
Dual Installation
STANDARD APPLICATION
Two overlay or stainless steel units may be placed side by
side in a dual installation. Some standard applications will
require a dual installation kit, available through your
authorized Sub-Zero dealer. If you are installing two units
side by side in a flush inset application, refer to page 32.
A custom filler strip can be used between two units in a
framed, overlay or stainless steel design application. It is
recommended that the filler strip be at least 2"
(51)
wide to
prevent condensation between the units. Be sure to add
the filler strip width to your rough opening width. Refer to
the full-scale template on page 42.
Dual installations without a filler strip can only be accom-
plished using two units with opposite hinges as shown in
illustration A below. The dual installations shown in illus-
trations B and C require a filler strip.
IMPORTANT NOTE:
For the application shown in illustra-
tion A, a dual installation accessory kit is required. Refer to
page 36 for information on dual installation kits.
Dual Installation Panel Requirements
MAX WEIGHT PER PANEL
BI-36R, BI-36RG and BI-36F
75 lbs
(34 kg)
All Other Models
50 lbs
(23 kg)
Dual Wide Grille Panel
26 lbs
(12 kg)
MIN PANEL THICKNESS
Framed Panels
1
/
4
"
(6)
Overlay and Flush Inset Panels
5
/
8
"
(16)
Illus. A
WITHOUT FILLER STRIP
FILLER STRIP REQUIRED
FILLER STRIP REQUIRED
Illus. B
Illus. C
Dual installation—standard application.