TASCAM HS-8 Firmware V1.40 Instruction Manual - Page 5

Network function FTP, Telnet and VNC details

Page 5 highlights

HS-8 Network function (FTP, Telnet and VNC) details FTP (file transfer protocol) By using an FTP client application, you can transfer files between this unit and a computer. Connect to this unit and login in the same way as with other FTP servers. After connecting and logging in, "A:" and "B:" will appear in the root directory. These correspond to the unit's CF1 and CF2 slots. If the corresponding slot does not contain a card, the "A:" or "B:" will appear empty. NOTE ii To display Japanese, use an FTP application that supports Unicode. ii Always set the maximum number of simultaneous transfers of the FTP client application to "1". If not set to "1" files cannot be transferred properly. ii For information about FTP client applications that have been confirmed to work properly with this unit, please contact TASCAM customer support. Required settings for connecting by FTP The following settings are necessary for connecting to this unit by FTP. IP address: This unit's IP address is shown in the IP Address field of the REMOTE SETUP screen ETHERNET page. Port: 21 User name: HS-8 (cannot be changed, case sensitive) Password: HS-8 (default, case sensitive) This setting can be changed by using the Password Change button on the REMOTE SETUP screen ETHERNET page. NOTE ii The number of simultaneous connections is "1". Depending on the FTP client application, two simultaneous connections with this unit might be possible, but files might not be transferred correctly, so we recommend that you do not use two or more simultaneous FTP connections with this unit. ii FTP connections cannot be made when EXTERNAL Control has been set to LOCK on the Lock Setup screen. Likewise, setting this to LOCK will end any active FTP connection. ii Changing any settings on the REMOTE SETUP screen of the ETHERNET page will also end any active FTP connection. Working with files using an FTP client application CAUTION When adding, overwriting or deleting files/folders from this unit using an FTP client application, always follow the procedures below to rebuild the entire CF card that was changed. If you do not rebuild the card, inconsistencies between the syetem files and audio files will occur, leading to problems such as the following. iiAdded files and folders will not appear iiDeleted files and folders will continue to appear iiOverwritten files will not play back properly Procedures for rebuilding the entire CF card 1. Open the project selection screen. 2. While no project is selected, press the MENU button to open a pull-up menu. 3. Press the REBUILD button in the pull-up menu. 4. When a confirmation message appears in a pop-up window, press the OK button or the DATA dial. pp Read files from the unit You can read files from this unit at any time. pp Add new files to the unit You can add files to this unit at any time. When recording, if you add BWF files to the current session, they will be shown in the list with existing files, recorded files and added files in that order. pp Overwrite existing files on the unit You can only overwrite the current take when the unit is stopped. You can overwrite other existing files at any time. However, if the PLAY SETUP screen GENERAL page Play Mode setting is All Take, during playback you might not be able to overwrite the take following the current take depending on the timing. pp Delete a file on the unit The current take can be deleted only when the unit is stopped. Files other than the current take can be deleted at any time. pp Add a new folder to this unit You can add a new folder to this unit at any time. pp Delete a folder from this unit You can only delete the current folder when stopped. You can delete any folder other than the current from this unit at any time. pp Edit the names of files/folders on this unit You cannot edit the names of files/folders on this unit. CAUTION ii If overwriting causes the size, number of channels, bit-rate or sampling frequency of an audio file to be different from the previous file, inconsistencies could occur between the system files and audio files. If such an inconsistency occurs, the following error message will appear when you start playback. ii Do not overwrite an existing audio file with a file that uses a different sampling frequency. The inconformity that results could become unresolvable. Remote control by Telnet Remote control of this unit is possible over Ethernet via port 23 using Telnet. Necessary setting for connections by Telnet The following settings are necessary for connecting to this unit by Telnet. IP address: This unit's IP address is shown in the IP Address field of the REMOTE SETUP screen ETHERNET page. Port: Password: 23 HS-8 (default, case sensitive) This setting can be changed by using the Password Change button on the REMOTE SETUP screen ETHERNET page. Connecting to the unit by Telnet 1. After connecting with this unit by Telnet using the above IP address and port number, press the computer Enter key. 2. When Enter Password appears on the Telnet console, input the above password and press the Enter key. 3. When login succeeds, Login Successful appears on the Telnet console. Input "exit"and press the Enter key to end the Telnet connection. NOTE ii 2 simultaneous Telnet connections are possible. ii Telnet connections cannot be made when EXTERNAL Control has been set to LOCK on the Lock Setup screen. Likewise, setting this to LOCK will end any active Telnet connections. ii Changing any settings on the REMOTE SETUP screen of the ETHERNET page will also end any active Telnet connection. ii The commands used for the telnet control are the same as for RS-232C control. Please see the RS-232C documentation available on our website and contact TASCAM customer support if additional help is needed. TASCAM HS-8 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

TASCAM HS-8
5
HS-8
Network function (FTP, Telnet and VNC) details
FTP (file transfer protocol)
By using an FTP client application, you can transfer files between this unit and
a computer.
Connect to this unit and login in the same way as with other FTP servers. After
connecting and logging in, “A:” and “B:” will appear in the root directory. These
correspond to the unit's CF1 and CF2 slots. If the corresponding slot does not
contain a card, the “A:” or “B:” will appear empty.
NOTE
i
To display Japanese, use an FTP application that supports Unicode.
i
Always set the maximum number of simultaneous transfers of the FTP client
application to “1”. If not set to “1” files cannot be transferred properly.
i
For information about FTP client applications that have been confirmed to
work properly with this unit, please contact TASCAM customer support.
Required settings for connecting by FTP
The following settings are necessary for connecting to this unit by FTP.
IP address:
This unit's IP address is shown in the
IP Address
field of the
REMOTE SETUP
screen
ETHERNET
page.
Port:
21
User name:
HS-8 (cannot be changed, case sensitive)
Password:
HS-8 (default, case sensitive)
This setting can be changed by using the
Password
Change
button on the
REMOTE SETUP
screen
ETH-
ERNET
page.
NOTE
i
The number of simultaneous connections is “1”. Depending on the FTP client
application, two simultaneous connections with this unit might be possible,
but files might not be transferred correctly, so we recommend that you do not
use two or more simultaneous FTP connections with this unit.
i
FTP connections cannot be made when EXTERNAL Control has been set to
LOCK on the
Lock Setup
screen. Likewise, setting this to LOCK will end
any active FTP connection.
i
Changing any settings on the
REMOTE SETUP
screen of the
ETHERNET
page will also end any active FTP connection.
Working with files using an FTP client application
CAUTION
When adding, overwriting or deleting files/folders from this unit using an FTP
client application, always follow the procedures below to rebuild the entire CF
card that was changed.
If you do not rebuild the card, inconsistencies between the syetem files and
audio files will occur, leading to problems such as the following.
i
Added files and folders will not appear
i
Deleted files and folders will continue to appear
i
Overwritten files will not play back properly
Procedures for rebuilding the entire CF card
1.
Open the project selection screen.
2.
While no project is selected, press the MENU button to open a pull-up
menu.
3.
Press the REBUILD button in the pull-up menu.
4.
When a confirmation message appears in a pop-up window, press the
OK button or the DATA dial.
p
Read files from the unit
You can read files from this unit at any time.
p
Add new files to the unit
You can add files to this unit at any time.
When recording, if you add BWF files to the current session, they will be
shown in the list with existing files, recorded files and added files in that
order.
p
Overwrite existing files on the unit
You can only overwrite the current take when the unit is stopped.
You can overwrite other existing files at any time.
However, if the
PLAY SETUP
screen
GENERAL
page
Play Mode
set-
ting is
All Take
, during playback you might not be able to overwrite
the take following the current take depending on the timing.
p
Delete a file on the unit
The current take can be deleted only when the unit is stopped. Files other
than the current take can be deleted at any time.
p
Add a new folder to this unit
You can add a new folder to this unit at any time.
p
Delete a folder from this unit
You can only delete the current folder when stopped.
You can delete any folder other than the current from this unit at any time.
p
Edit the names of files/folders on this unit
You cannot edit the names of files/folders on this unit.
CAUTION
i
If overwriting causes the size, number of channels, bit-rate or sampling
frequency of an audio file to be different from the previous file, inconsistencies
could occur between the system files and audio files. If such an inconsistency
occurs, the following error message will appear when you start playback.
i
Do not overwrite an existing audio file with a file that uses a different sampling
frequency. The inconformity that results could become unresolvable.
Remote control by Telnet
Remote control of this unit is possible over Ethernet via port 23 using Telnet.
Necessary setting for connections by Telnet
The following settings are necessary for connecting to this unit by Telnet.
IP address:
This unit’s IP address is shown in the
IP Address
field of the
REMOTE SETUP
screen
ETHERNET
page.
Port:
23
Password:
HS-8 (default, case sensitive)
This setting can be changed by using the
Password
Change
button on the
REMOTE SETUP
screen
ETH-
ERNET
page.
Connecting to the unit by Telnet
1.
After connecting with this unit by Telnet using the above IP address and
port number, press the computer
Enter
key.
2.
When
Enter Password
appears on the Telnet console, input the
above password and press the
Enter
key.
3.
When login succeeds,
Login Successful
appears on the Telnet
console. Input “exit”and press the Enter key to end the Telnet connection.
NOTE
i
2 simultaneous Telnet connections are possible.
i
Telnet connections cannot be made when
EXTERNAL Control
has been
set to
LOCK
on the
Lock Setup
screen. Likewise, setting this to LOCK will
end any active Telnet connections.
i
Changing any settings on the
REMOTE SETUP
screen of the
ETHERNET
page will also end any active Telnet connection.
i
The commands used for the telnet control are the same as for RS-232C control.
Please see the RS-232C documentation available on our website and contact
TASCAM customer support if additional help is needed.