Thermador CIT367XMS Installation Instructions - Page 9
Connect Electrical Supply, Check the Installation
View all Thermador CIT367XMS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
Connect Electrical Supply 9 CAUTION Before installing, turn off power supply at the service panel. Lock service panel to prevent power from being turned on accidentally. 9 CAUTION To reduce the risk of electric shock and fire, do not use a flexible power supply cord. Refer to rating label for more information. See "Customer Service" for rating label location. The maximum current rating of the branch-circuit breaker, the wire sizes and the connections must conform to the requirements of the National Electrical Code or Canadian Electrical Code and all local codes and ordinances. Attach flexible conduit to the junction box. Connect the lead wires to the junction box supply wires in proper phase: ▯ black (L1) to black ▯ red (L2) to red ▯ green or bare to ground Check the Installation 9 CAUTION Before you plug in an electrical cord or turn on power supply, make sure all controls are in the OFF position. Remove everything from the cooktop surface including stickers. Clean cooktop surface with cooktop cleaning cream. Switch on the circuit breaker. Verify that elements function properly. 1 House power supply cord 2 Black wire 3 Junction box 4 Cooktop power supply cord 5 Grounded green or bare cable 6 Certified UL connector 7 Red wire If the cooktop is installed and connected as specified above, it will be grounded in compliance with the National Electrical Code. 9