Thermador PH36GWS Installation instructions - Page 8
Installation Instructions
View all Thermador PH36GWS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Installation Instructions Installation Considerations Clearances and requirements The wall hood requires the ducting to be vented to the outside. It cannot be used in conjunction with a recirculation unit. Hood installation height above a cooktop, rangetop or range can vary. To obtain the necessary installation height above a cooktop, rangetop or range, consult the appliance's installation manual. inches (mm) Electrical Zone Hood Width The hood width should be no less than the width of the cooking surface. For proper performance, the housing must cover the entire cooking surface. For proper performance, the hood must be centered horizontally above the cooking surface. Where space is not restricted, a wider hood can be used to increase capture area. Distance From Cooking Surface The installation height ranges from a minimum height of 30'' (762 mm) to a suggested maximum height of 40'' (1,016 mm); however, it is necessary to follow the cooking appliance manufacturer's installation instructions for proper hood height. 8⅜" (212) 18" (457) Unit Weight This vent hood is heavy. Adequate structure and support must be provided in all types of installations. When calculating the load for the housing support system, be sure to consider the weight of the ventilation unit. 30" (762) - 40" (1,016) *Follow cooking appliance manufacturer's recommendations. NOTICE: The hood could incur some damage from heat if a Thermador Professional® series range or rangetop is operated with multiple burners at high settings under a hood that is installed at minimum clearances while the hood is turned off. Description Weight PH30HWS 62 lb (28 kg) PH36HWS 70 lb (32 kg) PH48HWS 85 lb (39 kg) PH36GWS 75 lb (34 kg) PH42GWS 84 lb (38 kg) PH48GWS 90 lb (41 kg) PH54GWS 96 lb (44 kg) PH60GWS 103 lb (47 kg) Integral Blower VTN1090R 23 lb (11 kg) Integral Blower VTN630W 11 lb (5 kg) NOTICE: The supplied weights address only the ventilation unit and blower. Installer must account for weight of any materials of construction when calculating the total dead weight load of installation, including but not limited to: wall, tile, mortar, plaster, brick, finishes, partitions, and other similarly incorporated architectural and structural items. It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations. Page. 8