Thermador PODC302 Design Guide - Built-In Ovens - Page 12
Installation Options - 30
View all Thermador PODC302 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
buILT-IN OvENS INSTALLATION OPTIONS WALL-MOuNTED INSTALLATION Thermador 30-inch Single Ovens may be installed in a wall cabinet that is a minimum of 24" deep and 30" wide. The cabinet base must be flat and capable of supporting a weight of at least 212 lbs. (96 kg). uNDER-cOuNTER INSTALLATION Thermador 30-inch Single Ovens may be installed below a Thermador induction, Electric or nonprofessional Gas Cooktop. When installing below a Thermador induction Cooktop, a minimum 1" air gap must be maintained between the bottom of the cooktop and the top of the oven. An electric or non-professional Thermador Gas Cooktop can be installed above a Thermador Single Built-in Oven as long as there is no contact between the bottom of the cooktop and the top of the oven. Thermador Built-in Ovens are designed and approved for installation with Thermador cooktops only. Refer to the cooktop section for additional specifications. Thermador 30-inch Single Ovens may also be installed above a Thermador warming drawer to create a convenient cooking center. Refer to the warming drawer section for additional specifications. IMPORTANT When a Thermador Oven is installed at the end of a cabinet run, adjacent to a perpendicular wall or cabinet door, it is good practice to allow at least 1/4" space between the side of the oven and the wall or door. For oven support, install 2 x 4's extending front to back flush with the bottom and the side of the opening. The supporting base must be well secured to the floor/ cabinet and level. The cabinet base must be flat and capable of supporting a weight of at least 212 lbs. (96 kg) for a 30-inch single oven. buILT-IN OvENS 30-INch SINGLE Models: POD301, ME301EP 30-inCH SinGLE OVEn-WALL-MOUnTED Door handle Projection Professional Series and Masterpiece Series with Professional Handle: 4 1/16" Electrical Location: The conduit box must be installed either above or below the unit. if the conduit box is installed below the unit, a 2"diameter hole or space is required between the back wall and the right rear of the 2 x 4 supports. 30-inCH SinGLE OVEn-UnDER-COUnTER Door handle Projection Professional Series and Masterpiece Series with Professional Handle: 4 1/16" 24" (610mm) 161/2" (419mm) 281/4" (718mm) 36" (915mm) min. 3" 20" (76mm) (508mm) 293/4" (755mm) 291/16" (738mm) 2713/16" (706mm) 281/2" (724mm) 27" (686mm) 43/4" (121mm) 237/8" (606mm) 22" (559mm) Electrical Location: it is recommended that the conduit box be placed 20" from the floor and 16 1/2" from the centerline of the cutout on the right side. A 2" diameter hole or space is required to route the conduit through the cabinetry. 1.800.735.4328 | THERMADOR.COM 83