Thermador PODC302 Design Guide - Built-In Ovens - Page 14

Wall-mounted Installation, Under-counter Installation, Important - model

Page 14 highlights

buILT-IN OvENS INSTALLATION OPTIONS WALL-MOuNTED INSTALLATION Thermador 30-inch Single Ovens may be installed in a wall cabinet that is a minimum of 24" deep and 30" wide. The cabinet base must be flat and capable of supporting a weight of at least 212 lbs. (96 kg). uNDER-cOuNTER INSTALLATION Thermador 30-inch Single Ovens may be installed below a Thermador induction, Electric or nonprofessional Gas Cooktop. When installing below a Thermador induction Cooktop, a minimum 1" air gap must be maintained between the bottom of the cooktop and the top of the oven. An electric or nonprofessional Thermador Gas Cooktop can be installed above a Thermador Single Built-in Oven as long as there is no contact between the bottom of the cooktop and the top of the oven. Thermador Built-in Ovens are designed and approved for installation with Thermador Cooktops only. Refer to the cooktop section for additional specifications. Thermador 30-inch Single Ovens may also be installed above a Thermador Warming Drawer to create a convenient cooking center. Refer to the warming drawer section for additional specifications. IMPORTANT When a Thermador Oven is installed at the end of a cabinet run, adjacent to a perpendicular wall or cabinet door, it is good practice to allow at least 1/4" space between the side of the oven and the wall or door. For oven support, install 2 x 4's extending front to back flush with the bottom and the side of the opening. The supporting base must be well secured to the floor/ cabinet and level. The cabinet base must be flat and capable of supporting a weight of at least 212 lbs. (96 kg) for a 30-inch single oven. buILT-IN OvENS 30-INch SINGLE Models: M301ES, ME301ES 30-inCH SinGLE OVEn-WALL-MOUnTED Door handle Projection Masterpiece Series: 3 11/16" Electrical Location: The conduit box must be installed either above or below the unit. if the conduit box is installed below the unit, a 2" diameter hole or space is required between the back wall and the right rear of the 2 x 4 supports. 30-inCH SinGLE OVEn-UnDER-COUnTER Door handle Projection Masterpiece Series: 3 11/16" 24" (610mm) 161/2" (419mm) 281/4" (718mm) 293/4" (755mm) 291/16" (738mm) 2713/16" (706mm) 281/2" (724mm) 27" (686mm) 36" (915mm) min. 3" 20" (76mm) (508mm) 43/4" (121mm) 237/8" (606mm) 22" (559mm) Electrical Location: it is recommended that the conduit box be placed 20" from the floor and 16 1/2" from the centerline of the cutout on the right side. A 2" diameter hole or space is required to route the conduit through the cabinetry. 1.800.735.4328 | THERMADOR.COM 85

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

85
1.800.735.4328
|
THERMADOR.COM
36
"
(915mm)
20
"
(508mm)
28
1/4"
(718mm)
16
1/2"
(419mm)
24
"
(610mm)
4
3/4"
(121mm)
28
1/2"
(724mm)
23
7/8"
(606mm)
22
"
(559mm)
29
1/16"
(738mm)
29
3/4"
(755mm)
27
"
(686mm)
27
13/16"
(706mm)
min. 3
"
(76mm)
BUILT-IN OVENS
BUILT-IN OVENS
30-INCH SINGLE
Models: M301ES, ME301ES
30-INCH SINGLE OVEN—WALL-MOUNTED
Electrical Location:
The conduit box must be installed either above
or below the unit. If the conduit box is installed below the unit, a
2" diameter hole or space is required between the back wall and the right
rear of the 2 x 4 supports.
30-INCH SINGLE OVEN—UNDER-COUNTER
Electrical Location:
It is recommended that the conduit box be placed
20" from the floor and 16
1
/
2
" from the centerline of the cutout on the right
side. A 2" diameter hole or space is required to route the conduit through
the cabinetry.
INSTALLATION OPTIONS
WALL-MOUNTED INSTALLATION
Thermador 30-inch Single Ovens may be installed in
a wall cabinet that is a minimum of 24" deep and 30"
wide. The cabinet base must be flat and capable of
supporting a weight of at least 212 lbs. (96 kg).
UNDER-COUNTER INSTALLATION
Thermador 30-inch Single Ovens may be installed
below a Thermador Induction, Electric or Non-
professional Gas Cooktop. When installing below
a Thermador Induction Cooktop, a minimum 1" air
gap must be maintained between the bottom of the
cooktop and the top of the oven. An electric or non-
professional Thermador Gas Cooktop can be installed
above a Thermador Single Built-in Oven as long as
there is no contact between the bottom of the cooktop
and the top of the oven. Thermador Built-in Ovens are
designed and approved for installation with Thermador
Cooktops only. Refer to the cooktop section for
additional specifications.
Thermador 30-inch Single Ovens may also be installed
above a Thermador Warming Drawer to create a
convenient cooking center. Refer to the warming
drawer section for additional specifications.
IMPORTANT
When a Thermador Oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, it is good practice to allow at least
1
/
4
" space
between the side of the oven and the wall or door.
For oven support, install 2 x 4’s extending front to back
flush with the bottom and the side of the opening. The
supporting base must be well secured to the floor/
cabinet and level.
The cabinet base must be flat and capable of
supporting a weight of at least 212 lbs. (96 kg) for
a 30-inch single oven.
Door Handle Projection
Masterpiece Series: 3
11
/
16
"
Door Handle Projection
Masterpiece Series: 3
11
/
16
"