Thermador PRD606RESG Product Specs - Page 4

Inch Range Dimensions And Clearance Requirements With Low Back

Page 4 highlights

PRD606RESG 60-INCH DUAL-FUEL PRO GRAND® RANGE WITH STEAM AND DOUBLE GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE Installation Clearances with Low Backguard 60-INCH RANGE DIMENSIONS AND CLEARANCE REQUIREMENTS WITH "LOW BACK" NOTE: A 36-inch minimum clearance is required between the top of the cooking surface and the bottom of an unprotected cabinet. A 30-inch clearance can be used when the bottom of the wood or metal cabinet is protected by not less than 1/4 inch of a flame retardant material covered with not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. 36" (914 mm) min. to combustible materials 31¼" (794 mm) 291/8" (740 mm) Combustible Materials 9" (229 mm) Lowback 357/8" (911 mm) Min. 36¾" (933 mm) Max. 251/8" (638 mm) max. recess depth Combustible Back Wall 267/8" (683 mm) 48¾" (1238 mm) As defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA. Clearances of less than 12" (305 mm) must be approved by the local codes and/or by the local authority having jurisdiction. Page 4 of 5 01 / 16

  • 1
  • 2
  • 3
  • 4
  • 5

Page 4 of 5
PRD606RESG
60-INCH DUAL-FUEL PRO GRAND
®
RANGE
WITH STEAM AND DOUBLE GRIDDLE
PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE
01 / 16
60-INCH RANGE DIMENSIONS AND CLEARANCE REQUIREMENTS WITH “LOW BACK”
NOTE:
A 36-inch
minimum clearance is
required between the top
of the cooking surface
and the bottom of an
unprotected cabinet. A
30-inch clearance can be
used when the bottom
of the wood or metal
cabinet is protected by
not less than
1
/
4
inch of a
flame retardant material
covered with not less
than No. 28 MSG sheet
steel, 0.015 inch (0.4 mm)
thick stainless steel, 0.024
inch (0.6 mm) aluminum,
or 0.020 inch (0.5 mm)
thick copper.
9" (229 mm)
Lowback
Combustible
Materials
31¼" (794 mm)
29
1
/
8
" (740 mm)
36" (914 mm) min.
to combustible
materials
25
1
/
8
" (638 mm)
max. recess depth
Combustible
Back Wall
35
7
/
8
" (911 mm) Min.
36¾" (933 mm) Max.
26
7
/
8
" (683 mm)
48¾" (1238 mm)
As defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12" (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.