Thermador SGSX365TS Installation instructions - Page 8

Mounting Requirements

Page 8 highlights

Note: All measurements given must be precisely followed. If nonstandard cabinets are used, make sure they are installed with minimum dimensions shown in image above. Plan the installation of the unit so that the power cord, gas shut-off valve and gas pressure regulator are accessible from the front of the cabinet. Countertop Requirements Notes ▯ All measurements given must be precisely followed. If nonstandard cabinets are used, make sure they are installed with minimum dimensions shown in image below. ▯ When installed in combination with a hood, refer to hood manufacturer's requirements for installation 30" Models 36" Models gas connection gas connection max. 3″ (76) ( )=mm * Side wall clearance dimensions can be reduced to 6" (152 mm) if opposing side wall is ≥ 24" (610 mm). Mounting Requirements Use the hold down brackets supplied. See "Install the Cooktop" section for further details. Ventilation Requirements We strongly recommend the installation of ventilation with the appliance. The appliance must be installed according to the furnished instructions. max. 3″ (76) ( )=mm * Side wall clearance dimensions can be reduced to 6" (152 mm) if opposing side wall is ≥ 24" (610 mm). 9 CAUTION The appliance should not be installed with a ventilation system that blows air downward toward the burners. This type of ventilation system may cause ignition and combustion problems with the gas cooking appliance resulting in personal injury or unintended operation. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

8
Note:
All measurements given must be precisely
followed. If nonstandard cabinets are used, make sure
they are installed with minimum dimensions shown in
image above.
Plan the installation of the unit so that the power cord,
gas shut-off valve and gas pressure regulator are
accessible from the front of the cabinet.
Countertop Requirements
Notes
All measurements given must be precisely followed. If
nonstandard cabinets are used, make sure they are
installed with minimum dimensions shown in image
below.
When installed in combination with a hood, refer to
hood manufacturer’s requirements for installation
30” Models
*
Side wall clearance dimensions can be reduced to 6”
(152 mm) if opposing side wall is
24” (610 mm).
36” Models
* Side wall clearance dimensions can be reduced to 6”
(152 mm) if opposing side wall is
24” (610 mm).
Mounting Requirements
Use the hold down brackets supplied. See “Install the
Cooktop” section for further details.
Ventilation Requirements
We strongly recommend the installation of ventilation with
the appliance. The appliance must be installed according
to the furnished instructions.
9
CAUTION
The appliance should not be installed with a
ventilation system that blows air downward toward
the burners. This type of ventilation system may
cause ignition and combustion problems with the
gas cooking appliance resulting in personal injury or
unintended operation.
( )=mm
max. 3″ (76)
gas
connection
max. 3″ (76)
( )=mm
gas
connection