Toshiba Tecra M2 Instruction Manual - Page 113
nd battery, Slim Select Bay, Power on, no operation, adaptor, connected, DC IN 15V
View all Toshiba Tecra M2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
Power and Power-Up Modes Table 6-1 Power conditions continued Power on AC adaptor not connected 2nd battery charge is above low battery trigger point • Operates • LED: 2nd battery off DC IN 15V off 2nd battery charge is below low battery trigger point • Operates • LED: 2nd battery flashes orange DC IN 15V off 2nd battery charge is exhausted Computer shuts down *3 No 2nd battery is installed • No operation *5 • LED: 2nd battery off DC IN 15V off Power off (no operation) 2nd battery indicator refers to the Slim Select Bay indicator when a secondary battery is installed. *1 When the 2nd battery is not charging. *2 When the main battery is not charging. *3 For the computer to shut down in hibernation mode, the hibernation feature must be enabled in two places in TOSHIBA Power Saver: the Hibernate window and the Battery Alarm item of the Alarm window. If a main battery and a 2nd battery are installed, the computer does not shut down until the charge in both batteries is exhausted. *4 When no 2nd battery is installed. *5 When no main battery is installed. When batteries are charged, the main battery is charged first. When it is fully charged, the 2nd battery is charged. User's Manual 6-3