Tripp Lite 5P750RC Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 10
Display functions, 6 User settings
![]() |
View all Tripp Lite 5P750RC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
ENGLISH 2.5 Display functions Press the Enter ( ) button to activate the menu options. Use the two middle buttons ( and ) to scroll through the menu structure. Press the Enter ( ) button to select an option. Press the button to cancel or return to the previous menu. Main menu Measurements Submenu Display information or Menu function Load W VA / Load A pf / Output V Hz / Input V Hz / Battery V min / Efficiency / Power usage Control Load Segments Start battery test Reset fault state Restore factory settings Reset power usage Group 1: ON / OFF Group 2: ON / OFF These commands overrule user settings for load segments. Starts a manual battery test Clears active faults Returns all settings to original values (UPS restart required) Clears power usage measurements Settings Fault log Identification Local settings In/Out settings On/Off settings Battery settings Fault list Reset fault list Sets product general parameters Sets Input and Output parameters Sets On/Off conditions Sets battery configuration Displays the faults stored Clears faults UPS Type / Part Number / Serial Number / Firmware release / Com card address 2.6 User settings The following table displays the options that can be changed by the user. Local settings Submenu Language LCD settings Audible alarm Output voltage Available settings Default settings [English] [Français] [Deutsch] [Español] [English] Português] [Italiano] [Simplified Chinese] [Japanese] Menus, status, notices and alarms, UPS User selectable when UPS is powered for the first time. fault, Event Log data and settings are in all supported languages. Modify LCD screen brightness and contrast to adapt to room light conditions . [Enabled] [Disabled on battery] [Always disabled] Enable or disable the buzzer if an alarm occurs. Enable [100V] [120V] [125V] User selectable when UPS is powered for the first time In/Out settings Input thresholds Sensitivity Load segments Auto start delay [Normal mode] [Extended mode] Extended mode reduces lower input voltage to 150 V before UPS transfers to battery. [High] [Low] High: for sensitive equipment, UPS will easily transfer to battery when utility conditions are becoming bad. [No Delay] [1 s] [2 s]... [65354 s] The connected load is powered after the specified delay. Normal mode High Group 1: 3 s Group 2: 6 s Load segments - Auto shutdown delay Overload prealarm [Disable] [0s] [1 s] [2 s]...[65354 s] During a power outage, authorises to keep some equipment running while turning off other equipment. [10 %] [15 %] [20 %] ... [100 %] [105 %] Gives a warning when a predefined critical percentage of load is Group 1: Disable Group 2: Disable [105 %] 5P 750VA-1.5 KVA US_EN Page 10
![](/manual_guide/products/tripp-lite-5p1500rc-eaton-5p750rc-5p1000rc-5p1500rc-ups-installation-user-manual-880f4a6/10.png)