Tripp Lite APS2012 Owner's Manual for APS Inverters 932748 - Page 5
Operation, Configuration
View all Tripp Lite APS2012 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Operation (continued) Resetting Your Inverter/Charger to Restore AC Power Your Inverter/Charger may cease supplying AC power or DC charging power in order to protect itself from overload or to protect your electrical system. To restore normal functioning: Overload Reset: Switch operating mode switch to "DC OFF" and remove some of the connected electrical load (ie: turn off some of the AC devices drawing power which may have caused the overload of the unit). Wait one minute, then switch operating mode switch back to either "AUTO/REMOTE" or "CHARGE ONLY." Output Circuit Breaker Reset: Alternatively, check output circuit breaker on the unit's front panel. If tripped, remove a portion of the electrical load, wait one minute to allow components to cool, then reset the circuit breaker. See the Troubleshooting section for additional possible reasons why AC output may be absent. Configuration Set Configuration DIP Switches Using a small tool, set the Configuration DIP Switches (located on the front panel, see diagram) to optimize Inverter/Charger operation depending on your application. B4 B3 B2 B1 A4 A3 A2 A1 Group B Dip Switches INPUT C/B 10A OUTPUT C/B 12A Group A Dip Switches Group A DIP Switches Using a small tool, configure your Inverter/Charger by setting the four Group A DIP Switches (located on the front panel of your unit; see diagram) as follows: A1 Select Battery Type-REQUIRED A4 A3 A2 A1 CAUTION: The Battery Type DIP Switch setting must match the type of batteries you connect, or your batteries may be degraded or damaged over an extended period of time. See "Battery Selection," for more information. Battery Type Switch Position Gel Cell (Sealed) Battery Up Wet Cell (Vented) Battery Down (factory setting) A2 Charger Inhibit Function Charger Inhibited Charger Enabled Charger A4 A3 A2 A1 Inhibited Charger Enabled Switch Position Up Down (factory setting) A4 A3 Select Low AC Input Voltage Point for Switching to Battery- OPTIONAL* A4 A3 A2 A1 A4 A3 A2 A1 A4 A3 A2 A1 A4 A3 A2 A1 Voltage Switch Position 105V 95V 85V 75V #A4 Up & #A3 Up #A4 Up & #A3 Down #A4 Down & #A3 Up #A4 Down & #A3 Down (factory setting) * Most of your connected appliances and equipment will perform adequately when your Inverter/Charger's Low AC Voltage Input Point (DIP Switches #3 and #4 of Group A are set to 95V. However, if the unit frequently switches to battery power due to momentary low line voltage swings that would have little effect on equipment operation, you may wish to adjust these settings. By decreasing the Low AC Voltage Point, you will reduce the number of times your unit switches to battery due to voltage swings. 5