Tripp Lite SU3000RTXLCD2U Owner's Manual for SU3000RTXLCD2U UPS System 9332C3 - Page 18
Disable, Scroll, Select
View all Tripp Lite SU3000RTXLCD2U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Operation 4 The OVERLOAD ALARM selection screen will appear. OVERLOAD ALARM refers to the point at which the UPS will sound its overload alarm. The factory setting of 105% will provide adequate overload warnings for most applications, but alternative values from 5% to the 105% default (in 5% intervals) are available for custom configurations. To Advance to To Change This the Next Screen: Setting: Press SCROLL (v) Press "SELECT" (^) 105%* SCROLL SELECT Press "SELECT" (^) to SET this value. Press "SCROLL" (v) to advance to the next option. Available values are: 5% to 105% (in 5% intervals) 5 The SHUTDOWN AFTER selection screen will appear. Scroll through available values and press SELECT (^) to SET. Factory default = 105% SHUTDOWN AFTER refers to the amount of runtime the UPS will provide in a power failure before turning off. The factory configuration of DISABLE is suitable for applications where the longest possible runtime is desired. In cases where a specific amount of runtime is needed (and no more), you can set the shutdown-after value to a specific number between 5 and 90 minutes (in 5 min. intervals), using this control. To Advance to To Change This the Next Screen: Setting: Press SCROLL (v) Press "SELECT" (^) DISABLE* SCROLL SELECT Press "SELECT" (^) to SET this value. Press "SCROLL" (v) to advance to the next option. Available values are: 5 to 90 minutes (in 5 min. intervals) 6 The BATTERY SAVE selection screen will appear. Scroll through available values and press SELECT (^) to SET. Factory default = DISABLE BATTERY SAVE option enables automatic UPS power-off in battery mode when there is no need for continued operation. This option prevents unnecessary battery discharge by shutting off UPS power once the load level falls below a user-selectable percentage for 10 continuous minutes. Settings are available to enable shutdown at load levels between 5% and 95% (in 5% increments). This feature is ideal for non-monitored UPS configurations where connected equipment consumes a significant amount of UPS capacity but is subsequently shut down, or when devices are connected to a UPS but are not powered on to begin with, and thus require no battery backup. Users may determine the ideal percentage setpoint by monitoring the UPS LCD load level screen for typical power consumption in both operating and shutdown modes. For example, if your equipment normally consumes 40-100% UPS capacity while operational, but drops to 3% once it's shut down, a BATTERY SAVE percentage setting of 5% would be ideal. Once connected equipment power consumption falls below the selected percentage for 10 continuous minutes, the UPS will turn off automatically, preventing unnecessary battery discharge. The factory default for this option is DISABLE. To Advance to To Change This the Next Screen: Setting: Press SCROLL (v) Press "SELECT" (^) DISABLE* SCROLL SELECT Press "SELECT" (^) to SET this value. Press "SCROLL" (v) to advance to the next option. Available values are: 5% to 95% (in 5% intervals) Scroll through available values and press SELECT (^) to SET. Factory default = DISABLE Continued on page19. 18 13-07-015-9332C3.indb 18 7/26/2013 11:16:25 AM