Tripp Lite SUINT3000LCD2U Owner s Manual for Single-Phase Rackmount On-line UP - Page 15

Power Strategy Selection Options

Page 15 highlights

Operations MAIN MENU / SUBMENU SETTINGS Basic setup (continued) Advanced setup DISPLAY / SETTING OPTIONS DISPLAY / SETTING DESCRIPTION Power strategy: • Auto-Adaptive • Max Efficiency • Max Quality • Freq. Regulation • Freq. Conversion to 60Hz • Freq. Conversion to 50Hz Battery: • External battery configuration o Configure via UPS o PC configured o Battery Replacement • Battery Age Alert System: • Display brightness o High o Medium (factory setting) o Low • Backlight dim: Enter 10-120 seconds (factory setting is 60 seconds) • Password: Set your 4 digit password (factory setting is 0000) • Factory reset (resets all UPS preferences to factory settings, including battery configurations) In/Out: • Overload Alert Lvl: Enter a value 5-105% (factory setting is 100%) • Conf. Fault Action (UPS response to fault) o Go to bypass (factory setting) o Go to standby • Bypass Low Limit: Enter a value -5% to -20% (factory setting is -15%) • Bypass High Limit: Enter a value +5% to +20% (factory setting is +10%) On/Off: • Cold Start o Enable (factory setting) o Disable • Auto Restart o Enable (factory setting) o Disable • Auto Restart Delay o Enter: 0 to 60 seconds (factory setting is 0 seconds) • Energy Saving o Enter: 0-100% o Disable (factory setting) • Off Mode o Standby o Bypass (factory setting) • Min. Batt to Restart o Enter: 10-90% o Disable (factory setting) Use the SETTINGS / BASIC / POWER STRATEGY option to display or set the UPS Power strategy. See Power Strategy Selection Options section under the Operations section for more info on the available power strategy options. Use the SETTINGS / BASIC / BATTERY option to configure the UPS with external battery packs. Battery replacement option can be used to update installation date for non-smart external battery replacement of the same type. Also sets the battery age alert duration for battery replacement reminder. See Configuring External Battery Packs section under the Operations section for information on how to configure external battery packs. Use the SETTINGS / ADVANCED / SYSTEM option to set the display brightness, the display backlight dim time-out, password or factory reset options. Use SETTINGS / ADVANCED / IN-OUT for these options: Sets the UPS output load percentage before an overload alert is sent. Sets the UPS response to fault conditions that require the UPS to exit double-conversion mode. GO TO BYPASS option maintains AC output (so long as input voltage is within bypass high/low limits). GO TO STANDBY option causes the UPS to turn off output AC in response to fault conditions. Specifies the lowest acceptable input voltage for bypass operation. Specifies the highest acceptable input voltage for bypass operation. Use SETTINGS / ADVANCED / ON-OFF for these options: Enabling Cold-start allows the UPS to be manually turned on into battery mode during a power failure. Enabling Auto-restart allows the UPS to automatically turn back on into a protected operating mode when power is restored. Auto-restart delay forces the UPS to wait 0-60 seconds after power is restored before automatically restarting. Requires that Auto-restart when power is restored be enabled. Energy saving enables the UPS to automatically shutdown when the output load is less than the selected percentage continuously for 5 minutes. Off mode setting of BYPASS allows the UPS to provide unregulated line power within configured bypass low / high limits to be available at the output of the UPS when it is turned off. Minimum battery charge level to restart forces the UPS to wait until batteries have recharged to the selected percentage before automatically restarting. Note: UPS can be manually started using the power button if battery is below the minimum battery restart threshold. Requires that Auto-restart when power is restored be enabled. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132

15
Operations
MAIN MENU / SUBMENU
DISPLAY / SETTING OPTIONS
DISPLAY / SETTING DESCRIPTION
SETTINGS
Basic setup
(continued)
Power strategy:
• Auto-Adaptive
• Max Efficiency
• Max Quality
• Freq. Regulation
• Freq. Conversion to 60Hz
• Freq. Conversion to 50Hz
Use the SETTINGS / BASIC / POWER STRATEGY option to display
or set the UPS Power strategy.
See
Power Strategy Selection Options
section under the
Operations
section for more info on the available power
strategy options.
Battery:
• External battery configuration
o
Configure via UPS
o
PC configured
o
Battery Replacement
• Battery Age Alert
Use the SETTINGS / BASIC / BATTERY option to configure the
UPS with external battery packs. Battery replacement option can
be used to update installation date for non-smart external
battery replacement of the same type. Also sets the battery age
alert duration for battery replacement reminder.
See
Configuring External Battery Packs
section under the
Operations
section for information on how to configure external
battery packs.
Advanced setup
System:
• Display brightness
o
High
o
Medium (factory setting)
o
Low
• Backlight dim: Enter 10-120 seconds
(factory setting is 60 seconds)
• Password: Set your 4 digit password
(factory setting is 0000)
• Factory reset (resets all UPS preferences
to factory settings, including battery
configurations)
Use the SETTINGS / ADVANCED / SYSTEM option to set the
display brightness, the display backlight dim time-out, password
or factory reset options.
In/Out:
• Overload Alert Lvl: Enter a value 5-105%
(factory setting is 100%)
Use SETTINGS / ADVANCED / IN-OUT for these options:
Sets the UPS output load percentage before an overload alert
is sent.
• Conf. Fault Action
(UPS response to fault)
o
Go to bypass (factory setting)
o
Go to standby
Sets the UPS response to fault conditions that require the UPS
to exit double-conversion mode.
GO TO BYPASS option
maintains AC output (so long as input voltage is within bypass
high/low limits).
GO TO STANDBY option causes the UPS to turn
off output AC in response to fault conditions.
• Bypass Low Limit: Enter a value -5% to
-20% (factory setting is -15%)
Specifies the lowest acceptable input voltage for bypass
operation.
• Bypass High Limit: Enter a value +5% to
+20% (factory setting is +10%)
Specifies the highest acceptable input voltage for bypass
operation.
On/Off:
• Cold Start
o
Enable (factory setting)
o
Disable
Use SETTINGS / ADVANCED / ON-OFF for these options:
Enabling Cold-start allows the UPS to be manually turned on
into battery mode during a power failure.
• Auto Restart
o
Enable (factory setting)
o
Disable
Enabling Auto-restart allows the UPS to automatically turn back
on into a protected operating mode when power is restored.
• Auto Restart Delay
o
Enter: 0 to 60 seconds
(factory setting is 0 seconds)
Auto-restart delay forces the UPS to wait 0-60 seconds after
power is restored before automatically restarting.
Requires that Auto-restart when power is restored be enabled.
• Energy Saving
o
Enter: 0-100%
o
Disable (factory setting)
Energy saving enables the UPS to automatically shutdown when
the output load is less than the selected percentage
continuously for 5 minutes.
• Off Mode
o
Standby
o
Bypass (factory setting)
Off mode setting of BYPASS allows the UPS to provide
unregulated line power within configured bypass low / high limits
to be available at the output of the UPS when it is turned off.
• Min. Batt to Restart
o
Enter: 10-90%
o
Disable (factory setting)
Minimum battery charge level to restart forces the UPS to wait
until batteries have recharged to the selected percentage before
automatically restarting.
Note:
UPS can be manually started using the power button if battery is
below the minimum battery restart threshold.
Requires that Auto-restart when power is restored be enabled.