Power Strategy Selection Options
View all Tripp Lite SUINT3000LCD2U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Operations MAIN MENU / SUBMENU SETTINGS Basic setup (continued) Advanced setup DISPLAY / SETTING OPTIONS DISPLAY / SETTING DESCRIPTION Power strategy: • Auto-Adaptive • Max Efficiency • Max Quality • Freq. Regulation • Freq. Conversion to 60Hz • Freq. Conversion to 50Hz Battery: • External battery configuration o Configure via UPS o PC configured o Battery Replacement • Battery Age Alert System: • Display brightness o High o Medium (factory setting) o Low • Backlight dim: Enter 10-120 seconds (factory setting is 60 seconds) • Password: Set your 4 digit password (factory setting is 0000) • Factory reset (resets all UPS preferences to factory settings, including battery configurations) In/Out: • Overload Alert Lvl: Enter a value 5-105% (factory setting is 100%) • Conf. Fault Action (UPS response to fault) o Go to bypass (factory setting) o Go to standby • Bypass Low Limit: Enter a value -5% to -20% (factory setting is -15%) • Bypass High Limit: Enter a value +5% to +20% (factory setting is +10%) On/Off: • Cold Start o Enable (factory setting) o Disable • Auto Restart o Enable (factory setting) o Disable • Auto Restart Delay o Enter: 0 to 60 seconds (factory setting is 0 seconds) • Energy Saving o Enter: 0-100% o Disable (factory setting) • Off Mode o Standby o Bypass (factory setting) • Min. Batt to Restart o Enter: 10-90% o Disable (factory setting) Use the SETTINGS / BASIC / POWER STRATEGY option to display or set the UPS Power strategy. See Power Strategy Selection Options section under the Operations section for more info on the available power strategy options. Use the SETTINGS / BASIC / BATTERY option to configure the UPS with external battery packs. Battery replacement option can be used to update installation date for non-smart external battery replacement of the same type. Also sets the battery age alert duration for battery replacement reminder. See Configuring External Battery Packs section under the Operations section for information on how to configure external battery packs. Use the SETTINGS / ADVANCED / SYSTEM option to set the display brightness, the display backlight dim time-out, password or factory reset options. Use SETTINGS / ADVANCED / IN-OUT for these options: Sets the UPS output load percentage before an overload alert is sent. Sets the UPS response to fault conditions that require the UPS to exit double-conversion mode. GO TO BYPASS option maintains AC output (so long as input voltage is within bypass high/low limits). GO TO STANDBY option causes the UPS to turn off output AC in response to fault conditions. Specifies the lowest acceptable input voltage for bypass operation. Specifies the highest acceptable input voltage for bypass operation. Use SETTINGS / ADVANCED / ON-OFF for these options: Enabling Cold-start allows the UPS to be manually turned on into battery mode during a power failure. Enabling Auto-restart allows the UPS to automatically turn back on into a protected operating mode when power is restored. Auto-restart delay forces the UPS to wait 0-60 seconds after power is restored before automatically restarting. Requires that Auto-restart when power is restored be enabled. Energy saving enables the UPS to automatically shutdown when the output load is less than the selected percentage continuously for 5 minutes. Off mode setting of BYPASS allows the UPS to provide unregulated line power within configured bypass low / high limits to be available at the output of the UPS when it is turned off. Minimum battery charge level to restart forces the UPS to wait until batteries have recharged to the selected percentage before automatically restarting. Note: UPS can be manually started using the power button if battery is below the minimum battery restart threshold. Requires that Auto-restart when power is restored be enabled. 15