Uniden BCT8 English Owners Manual - Page 54
must be set up as the First Unit, and the other must be set as the Clone Unit. - remote
UPC - 050633650349
View all Uniden BCT8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
To connect the Scanner to Scanner: Plug the male end of the RS232C straight interface cable into the remote port on the rear of one of the two scanners. Then connect the DB-9 to DB-9 null modem adapter to the cable. Plug the other end of the null modem adapter into the other scanner (DB9 Gender Changers are also available at your local electronics store.). Null Modem Adapter Pin connections Female DB9 1 2 3 4 5 6 7 8 9 Male DB9 4 3 2 6 & 1 5 4 8 7 Not used ANT. EXT. SP. DC 12V REMOTE ANT. EXT. SP. DC 12V REMOTE You can clone all of the programming of one BCT8 into another, including frequencies, talkgroup IDs, delay settings, etc. After connecting the two scanners, turn the radios ON. Prepare each scanner for clone mode as follows. After connecting the two scanners, make sure the scanners are turned off. 1. While you press and hold E, turn the radio on for each scanner. 2. Determine the scanner which has the frequency data that you want to transfer. This one must be set up as the "First Unit", and the other must be set as the "Clone Unit". 3. On the scanner that is the "Clone Unit", use the or key to select , then press HOLD/RESUME. 4. On the scanner that is the "First Unit", use the or key to select , then press HOLD/RESUME. 50