Remote Control Pass-through Mode, IR Pass Through-Func°on format, Reply: Command Type=p
![]() |
View all ViewSonic IFP9850 Gen 4 - 98" ViewBoard 4K Ultra HD Interactive Flat Panel manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
Remote Control Pass-through Mode When the PC sets the Display to Remote Control Pass through mode, the Display shall send a 7-byte packet (followed by "CR") in response to remote control unit (RCU) button activation. In this mode the remote control shall have no effect on the Display function. For example: "Volume+" will not change the volume of the Display, but instead only sends the "Volume+" code to the PC over the RS-232 port. IR Pass Through-Function format Reply: (Command Type="p") Name Length ID Byte Count 1 Byte 2 Byte Bytes order 1 2~3 Command Type 1 Byte 4 RCU Code1 RCU Code2 (MSB) (LSB) 1 Byte 1 Byte 5 6 CR 1 Byte 7 Example 1: Remote Control Pass-through when "VOL+" key is pressed for Display (#5) Send (Hex Format) Name Length ID Hex 0x36 0x30 0x35 Command Type 0x70 RCU Code1 RCU Code2 (MSB) (LSB) 0x31 0x30 CR 0x0D Key 1 2 3 4 5 6 7 8 9 0 RECALL (LAST) INFO (DISPLAY) ASPECT (ZOOM, SIZE) VOLUME UP (+) Code (HEX) 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 Basic *3.1.1 V V V V V V V V V V V Optional *3.1.1 V V V V 120