ViewSonic PJ1173 PJ1173 User Guide, English - Page 97

Projector Management using SNMP

Page 97 highlights

Management with Web browser software Projector Management using SNMP The SNMP (Simple Network Management Protocol) enables to manage the projector information, which is a failure or warning status, from the computer on the network. The SNMP management software will be required on the computer to use this function. NOTE • It is recommended that SNMP functions be carried out by a network administrator. • SNMP management software must be installed on the computer to monitor the projector via SNMP. SNMP Settings Configure the following items via a web browser to use SNMP. Example: If the IP address of the projector is set to 192.168.1.10: 1) Enter "http://192.168.1.10/" into the address bar of the web browser. 2) Enter the Administrator ID and Password and click [Logon]. 3) Click [Port Settings] on the main menu. 4) Click [Enable] check box to open the SNMP Port. Set the IP address to send the SNMP trap to when a Failure/Warning occurs. NOTE • A Network Restart is required after the SNMP Port configuration settings have been changed. Click [Network Restart] and configure the following items. 5) Click [Security Settings] on the main menu. 6) Click [SNMP] and set the community name on the screen that is displayed. NOTE • A Network Restart is required after the Community Name has been changed. Click [Network Restart] and configure the following items. 7) Configure the settings for Trap transmission of Failures/Warnings. Click [Alert Settings] on the main menu and select the Failure/Warning item to be configured. 8) Click [Enable] check box to send out the SNMP trap for Failures/Warnings. Clear [Enable] check box when SNMP trap transmission is not required. 9) Click [Apply] button to save the settings. ViewSonic 92 PJ1173

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

PJ1173
ViewSonic
Management with Web browser software
Projector Management using SNMP
The SNMP (Simple Network Management Protocol) enables to manage the
projector information, which is a failure or warning status, from the computer on
the network. The SNMP management software will be required on the computer
to use this function.
• It is recommended that SNMP functions be carried out by a network
administrator.
• SNMP management software must be installed on the computer to monitor
the projector via SNMP.
NOTE
SNMP Settings
Configure the following items via a web browser to use SNMP.
Example: If the IP address of the projector is set to 192.168.1.10:
±) Enter
into the address bar of the web browser.
2) Enter the Administrator ID and Password and click
[Logon]
.
3) Click
[Port Settings]
on the main menu.
4) Click
[Enable]
check box to open the
SNMP Port
. Set the IP address to send
the SNMP trap to when a Failure/Warning occurs.
5) Click
[Security Settings]
on the main menu.
6) Click
[SNMP]
and set the community name on the screen that is displayed.
7) Configure the settings for Trap transmission of Failures/Warnings. Click
[Alert Settings]
on the main menu and select the Failure/Warning item to be
configured.
8) Click
[Enable]
check box to send out the SNMP trap for Failures/Warnings.
Clear
[Enable]
check box when SNMP trap transmission is not required.
9) Click
[Apply]
button to save the settings.
• A Network Restart is required after the
Community Name
has been
changed. Click
[Network Restart]
and configure the following items.
NOTE
• A Network Restart is required after the
SNMP Port
configuration
settings have been changed. Click
[Network Restart]
and configure the
following items.