Viking AD51620 Outdoor Kitchen Planning Guide - Page 15
Outdoor
![]() |
View all Viking AD51620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Outdoor Planning Your Viking Outdoor Kitchen Note: If a VFLR4 is used in an island setting, a VBPFLR4 is used as the back panel. INSTALLATIONS REQUIRE A 4"W. FILLER STRIP There are several situations where 4"W. back panel (VBPFLR4) and back panels need to be used. The VLFR4 is a 4"W., 34-11/42"H. (includes 4-11/42" toe kick area) stainless steel "post" sandwiched between two cabinets. 1. Use a 4"W. filler whenever two Viking appliances are installed side-by-side in the run. This will give the appliances ample room for any clearance issues they may have in their general specifications. Remember that 8" is required for proper installation of the rotisserie motor on a grill. 2. Use a 4"W. back panel whenever a Viking outdoor grill is used in a layout against a non-combustible surface (such as a brick wall). The general specifications for the grill require 3" of space between the back of the grill and any noncombustible surface. The 4"W. back panel accounts for this. (See sample drawing on page 9) 3. If a VFLR4 is used in an island setting, a VBPFLR4 is used as the back panel. 4. Use the 4"W. filler whenever extra room in your cabinet layout is desired. INSTALLATIONS REQUIRING 90° AND 135° INNER AND OUTER FILLER STRIP Many installations include a "turn" in the layout. These turns can folloW. a back wall, or they may exist in an island setting. If a layout such as this is designed, 90 or 135 degree filler strips will need to be used. IMPORTANT: When using a VCF90, do not install a warming drawer base cabinet directly adjacent to a VBO1830 or VTPO1810. The cabinet drawers will not be allowed to fully extend due to the warming drawer handle. WHEN TO USE INSIDE FILLER STRIPS BY THEMSELVES (SEE SAMPLE DRAWING BELOW) Use a 90° (VCF90) or 135° (VCF135) inside filler whenever you have a 90 or 135 degree turn. If the layout is against a wall, no outer corner filler will be needed. The countertop will run into the wall. Your locally-supplied countertop installer will need to account for the void area underneath the countertop that falls in between the cabinets. VBPFLR4 (stainless facing out) NON-COMBUSTIBLE SURFACE VSP30 VBO1811 VBBO1601 VQBO4121 VFLR4 VCF90 NON-COMBUSTIBLE SURFACE VBO1811 VBBO2602 VTSP30 VBPFLR4 (stainless facing out) 15
![](/manual_guide/products/viking-vgbq53024-outdoor-kitchen-planning-guide-d32bae5/15.png)