Page 2 highlights

IMPORTANT: PLEASE READ AND FOLLOW •Before beginning, please read these instructions completely and carefully. •Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. •Please observe all local and national codes and ordinances. •Please ensure that this product is properly grounded. •The installer should leave these instructions with the consumer who should retain for local inspector's use and for future reference. •Installation must conform with local codes or, in the absence of codes, the National Electrical Code, ANSI/NFPA 70-latest edition. IN CANADA: Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes. GENERAL INFORMATION 1. WARNING: The use of cabinets for storage above the appliance may result in potential burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 in. beyond the bottom of the cabinets. 2. WARNING: This appliance shall not be used for space heating. This information is based on safety considerations. 3. All openings in the wall behind the appliance in the floor under the appliance shall be sealed. 4. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors. 5. Disconnect the electric supply to the appliance before cleaning or servicing. 6. When removing the cooktop for service and/or cleaning, disconnect AC power supply. 7. Electrical Requirement: Listed on Specifications - Minimum Recommended Electric Circuit. WARNING! ELECTRICAL GROUNDING INSTRUCTIONS This cooktop must be electrically grounded in accordance with local codes or, in the absence of codes, with the National Electrical Code, ANSI/NFPA 70-latest edition. 2 SPECIFICATIONS - VECU ELECTRIC COOKTOP Description Cutout Width VECU106 30" W. Minimum 28 3/4" (73.0 cm) VECU166 36" W. Minimum 34 3/4" (88.3 cm) Maximum 29 5/8" (75.2 cm) Maximum 35 1/2" (90.2 cm) Cutout Height Minimum - 3 1/8" (7.9 cm) Cutout Depth Minimum - 19 1/8" (48.6 cm) Maximum - 19 7/8" (50.5 cm) Overall Width 30 3/4" (78.1 cm) 36 3/4" (93.3 cm) Overall Height from Bottom 5" (12.7 cm) Overall Depth from Rear 21" (53.3 cm) Electrical Requirements 240 - 208/120 VAC/60 Hz - 3-wire conduit with a No. 10 ground wire. 40 amp connection 60 amp connection Maximum Amp Usage 240V 8.4 kW; 35.0 amps 11.8 kW 49.2 amps 208V 6.3 kW; 30.3 amps 8.9 kW 42.6 amps Surface Element Rating 240V 208V 240V 208V Right Front Right Rear Center Front Bridge Center Rear Left Front Left Rear 1500 2500 N/A 800 N/A 1800 1800 1125 watts 1875 watts N/A 600 watts N/A 1350 watts 1350 watts 1200 2500 1800 800 1800 2200 1500 900 watts 1875 watts 1350 600 watts 1350 1650 watts 1125 watts Approximate Shipping Weight 52 lb. (23.4 kg) 63 lb. (28.4 kg) SPECIFICATIONS - DECU ELECTRIC COOKTOP Description Cutout Width DECU106 30" W. Minimum 28 5/8" (72.7 cm) DECU166 36" W. 34 3/4" (88.3 cm) DECU155 45" W. 42 7/8" (108.9 cm) Maximum 29 7/8" (75.9 cm) 35 7/8" (91.1 cm) 44 1/8" (112.1 cm) Cutout Height Minimum 3 1/8" (7.9 cm) Cutout Height with Conduit 4 1/8" (10.5 cm) Cutout Depth Minimum 19 3/4" (50.2 cm) Maximum - 20 1/8" (51.1 cm) Overall Width 30 3/4" (78.1 cm) 36 3/4" (93.3 cm) 45" (114.3 cm) Overall Height from Bottom 4 1/2" (11.4 cm) Overall Depth from Rear 21" (53.3 cm) Electrical Requirements 240 - 208/120 VAC/60 Hz - 3-wire conduit with a No. 10 ground wire. Connect with lo- cally supplied 3-wire with ground, flexible cord rated 60 amp 125-250 VAC minimum. Cord must be agency approved for use with household electric cooktops. Maximum Amp Usage 240V 8.4 kW; 35.0 amps 10.9 kW; 44.0 amps 11.8 kW: 49.0 amps 208V Surface Element Rating Right Front Right Rear Center Right Center Left Left Front Bridge Left Rear 6.3 kW; 30.0 amps 240V 208V 1500 2500 N/A N/A 1800 800 1800 1125 watts 1875 watts N/A N/A 1350 watts 600 watts 1350 watts 8.2 kW; 34.0 amps 240V 208V 1500 2200 2500 N/A 1800 800 1800 1125 watts 1650 watts 1875 watts N/A 1350 watts 600 watts 1350 watts 8.9 kW; 43.0 amps 240V 208V 1500 2200 1200 2500 1800 800 1800 1125 watts 1650 watts 900 watts 1875 watts 1350 watts 600 watts 1350 watts Approximate Shipping Weight 52 lb. (23.4 kg) 60 lb. (27.0 kg) 71 lb. (32.0 kg) 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

2
IMPORTANT:
PLEASE READ AND FOLLOW
•Before beginning, please read these instructions completely and carefully.
•Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•Please observe all local and national codes and ordinances.
•Please ensure that this product is properly grounded.
•The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future
reference.
•Installation must conform with local codes or, in the absence of codes, the National Electrical Code, ANSI/NFPA 70-lat-
est edition.
IN CANADA: Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1
and/or local codes.
GENERAL INFORMATION
1.
WARNING:
The use of cabinets for storage above the appliance may result in potential burn hazard. Combustible
items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to provided the risk can be
reduced by installing a range hood that projects horizontally a minimum of 5 in. beyond the bottom of the cabinets.
2.
WARNING:
This appliance shall not be used for space heating. This information is based on safety considerations.
3. All openings in the wall behind the appliance in the floor under the appliance shall be sealed.
4. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.
5. Disconnect the electric supply to the appliance before cleaning or servicing.
6. When removing the cooktop for service and/or cleaning, disconnect AC power supply.
7. Electrical Requirement: Listed on Specifications - Minimum Recommended Electric Circuit.
ELECTRICAL GROUNDING INSTRUCTIONS
This cooktop must be electrically grounded in ac-
cordance with local codes or, in the absence of
codes,
with
the
National
Electrical
Code,
ANSI/NFPA 70-latest edition.
3
Description
DECU106
30” W.
DECU166
36” W.
DECU155
45” W.
Cutout Width
Minimum
28 5/8” (72.7 cm)
34 3/4” (88.3 cm)
42 7/8” (108.9 cm)
Maximum
29 7/8” (75.9 cm)
35 7/8” (91.1 cm)
44 1/8” (112.1 cm)
Cutout Height
Minimum 3 1/8” (7.9 cm)
Cutout Height with Conduit
4 1/8” (10.5 cm)
Cutout Depth
Minimum 19 3/4” (50.2 cm)
Maximum - 20 1/8” (51.1 cm)
Overall Width
30 3/4” (78.1 cm)
36 3/4” (93.3 cm)
45” (114.3 cm)
Overall Height from Bottom
4 1/2” (11.4 cm)
Overall Depth from Rear
21” (53.3 cm)
Electrical Requirements
240 - 208/120 VAC/60 Hz - 3-wire conduit with a No. 10 ground wire. Connect with lo-
cally supplied 3-wire with ground, flexible cord rated 60 amp 125-250 VAC minimum.
Cord must be agency approved for use with household electric cooktops.
Maximum Amp Usage
240V
8.4 kW; 35.0 amps
10.9 kW; 44.0 amps
11.8 kW: 49.0 amps
208V
6.3 kW; 30.0 amps
8.2 kW; 34.0 amps
8.9 kW; 43.0 amps
Surface Element Rating
240V
208V
240V
208V
240V
208V
Right Front
1500
1125 watts
1500
1125 watts
1500
1125 watts
Right Rear
2500
1875 watts
2200
1650 watts
2200
1650 watts
Center
Right
N/A
N/A
2500
1875 watts
1200
900 watts
Center Left
N/A
N/A
N/A
N/A
2500
1875 watts
Left Front
1800
1350 watts
1800
1350 watts
1800
1350 watts
Bridge
800
600 watts
800
600 watts
800
600 watts
Left Rear
1800
1350 watts
1800
1350 watts
1800
1350 watts
Approximate Shipping Weight
52 lb. (23.4 kg)
60 lb. (27.0 kg)
71 lb. (32.0 kg)
SPECIFICATIONS - DECU ELECTRIC COOKTOP
Description
VECU106
30” W.
VECU166
36” W.
Cutout Width
Minimum
28 3/4” (73.0 cm)
Minimum
34 3/4” (88.3 cm)
Maximum
29 5/8” (75.2 cm)
Maximum
35 1/2” (90.2 cm)
Cutout Height
Minimum - 3 1/8” (7.9 cm)
Cutout Depth
Minimum - 19 1/8” (48.6 cm)
Maximum - 19 7/8” (50.5 cm)
Overall Width
30 3/4” (78.1 cm)
36 3/4” (93.3 cm)
Overall Height from Bottom
5” (12.7 cm)
Overall Depth from Rear
21” (53.3 cm)
Electrical Requirements
240 - 208/120 VAC/60 Hz - 3-wire conduit with a No. 10 ground wire.
40 amp connection
60 amp connection
Maximum Amp Usage
240V
8.4 kW; 35.0 amps
11.8 kW
49.2 amps
208V
6.3 kW; 30.3 amps
8.9 kW
42.6 amps
Surface Element Rating
240V
208V
240V
208V
Right Front
1500
1125 watts
1200
900 watts
Right Rear
2500
1875 watts
2500
1875 watts
Center Front
N/A
N/A
1800
1350
Bridge
800
600 watts
800
600 watts
Center Rear
N/A
N/A
1800
1350
Left Front
1800
1350 watts
2200
1650 watts
Left Rear
1800
1350 watts
1500
1125 watts
Approximate Shipping Weight
52 lb. (23.4 kg)
63 lb. (28.4 kg)
SPECIFICATIONS - VECU ELECTRIC COOKTOP
WARNING!