Viking DFUW1541CR Installation Instructions - Page 10
Function, Function Access
View all Viking DFUW1541CR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
55˚ SETTING THE CONTROLS - DUAL ZONE The temperature of the wine cellar ranges from 40ºF (4ºC) to 65°F (18ºC). TruProtect™ "Basic" Function "Quick" Reference Solid Door Dual Zone Models: 64 ˚F 42 ˚F ON Hi/Low Temp Upper Hi/Low Temp Lower Function Turn Unit On & Off Function Access Pressing and holding the ON OFF key for 5-seconds will turn the unit "ON" or "OFF". Adjust Temperature Set-Point To adjust temperature set-point, press the SET key. When a compartment is in "SET" mode, a "SET" icon will be displayed. Pressing either the WARMER or COLDER keys located on the display pad will raise or lower the set temperature by one (1) °F or °C (depending on your setting). Display "Actual" Temperature Display represents "real-time" temperature of each compartment's stored wine and/or contents. Some minor temperature fluctuation around your desired set-point is normal. Select °F or °C Display Black-Out Mode Display Lighting Sabbath Mode Pressing the ˚F/C key will toggle the display between Fahrenheit and Centigrade temperature display. Display automatically shuts off when the door is closed. Display lighting can be enabled with the door closed by pressing the LIGHT key. Press and hold the SET key while pressing the ˚F/C key four (4) times in seven (7) seconds. TruProtect™ System System monitoring is automatically enabled unless system has been shut off (see below). Door Ajar Alarm High/Low Temp Alarm Power Failure Alarm Reset Alarms Disable/Enable TruProtect™ For Door Ajar Alarm, TruProtect must be Enabled, (See "Disable/Enable TruProtect", described below.) NOTE: Alarm may occur when changing set-points in excess of 10ºF, and/or high usage, this is normal. TruProtect must be Enabled, (See "Disable/Enable TruProtect", described below.) NOTE: Alarm will occur upon initial installation, since unit was run at factory to verify quality, this is normal. TruProtect must be Enabled, (See "Disable/Enable TruProtect", described below.) Close door to reset "DOOR AJAR" Alarm. Press the ON key to reset all other alarms. OFF Press and hold the key for five (5) seconds to enable or disable the TruProtect™ SET System. 18 Glass Door Dual Zone Models: 64 ˚F Place new control here when I get it from Ray 42 ˚F ON Hi/Low Temp Upper Hi/Low Temp Lower Control Confirmation/Comment Display will be blank when the refrigeration system is off. Lights will still function, but will time-out in 15 minutes after each activation if door is left open or display lighting is on, to prevent overheating. "SET" mode will automatically time-out in ten (10) seconds and default to actual content temperature if no keypad activity occurs, or you may exit "SET" mode by pressing the SET key until "SET" icon disappears. Temperature variation in "compartment" air, above and below set-point, is a normal effect of the refrigeration system cycling on and off. Stored items will not experience the full temperature swing of the compartment air due to the dampening effect of their thermal mass. 55 ˚F = 13 ˚C In addition, the control panel is hidden when the door is closed. Display lighting stays on continuously. The display will flash SA to confirm your selection, then the unit will enter Sabbath Mode. The display, audible alarms, message center and lights will be disabled. Sabbath Mode will automatically time-out in 72 hours, or can be exited by repeating the enabling process. TruProtect™ System message center displays a green "ON" when TruProtect™ is enabled and an amber "OFF" when TruProtect™ is disabled. An audible alarm will sound 3 times every 30 seconds and the message center will display an amber "DOOR AJAR". An audible alarm will sound 6 times every minute and the message center will display a red "HI/LOW TEMP UPPER" or a red "HI/LOW TEMP LOWER" if product temperature excursions occur for a duration outside acceptable limits. The message center will display an amber "POWER FAILURE" whenever power is interrupted to the unit. There is no audible alarm with a power failure. Although pressing the ON OFF key resets the alarms, the alarm will resume if the "alarm condition" still exists. The message center displays a green "ON" when the alarms are enabled. 19