Viking TVDR3602GDB Installation Instructions - Page 11

Wall Installation, Island Installation

Page 11 highlights

Clearance Dimensions The bottom of a standard hood should be 30" (76.2 cm) min. to 36" (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66" (167.6 cm) to 72" (182.9 cm) above the floor. Refer to the range hood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood. 66" min (167.6 cm) to Wall Installation 72" max (182.9 cm) 36" (91.4 cm) 12" (30.5 cm) *optional duct cover 18" (45.7 cm) 30" min (76.2 cm) to 36" max (91.4 cm) Island Installation 66" (167.6 cm) min to 72" (182.9) max 6" (15.2 cm) 30" (76.2 cm) 30" (76.2 cm) min to 36" (91.4) max Note: Clearances from noncombustible materials are not part of the ANSI Z21.1 scope and not certified by CSA. Clearances to non-combustible materials must be approved by the authority having jurisdiction. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

11
Clearance Dimensions
The bottom of a standard hood should be 30”
(76.2 cm) min. to 36” (91.4 cm) max. above
the countertop. This would typically result
in the bottom of the hood being 66” (167.6
cm) to 72” (182.9 cm) above the floor. Refer
to the range hood installation instructions
for additional information. These dimensions
provide for safe and effi
cient operation of the
hood.
Note
: Clearances from non-
combustible materials are not part
of the ANSI Z21.1 scope and not
certified by CSA. Clearances to
non-combustible materials must
be approved by the authority
having jurisdiction.
Wall Installation
Island Installation
30” min (76.2 cm)
to
36” max (91.4 cm)
36”
(91.4 cm)
18”
(45.7 cm)
12”
(30.5 cm)
*optional duct cover
66” min (167.6 cm)
to
72” max (182.9 cm)
30”
(76.2
cm)
66”
(
1
67.6
cm)
min
to
72”
(
1
82.9)
max
6”
(
1
5.2
cm)
30”
(76.2
cm)
min
to
36”
(9
1
.4)
max