Viking VBCV36381 Installation Instructions - Page 18

Installation, Duct Cover Option

Page 18 highlights

Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Duct Cover Option (VWH 10"H. Wall Hoods w/Standard Ventilator) Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. Installation (VWH 10"H. Wall Hoods w/Recirculating Kit) Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood upside down on recirculating unit. 34 Attach with screws and lock washers provided. Remove electrical box cover. Attach with screws. WARNING To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Flip hood over. Insert 6" of electrical wiring through the top of vent hood and secure. Refer to local codes. CAUTION: Secure vent hood. Make sure mounting screws are secured into framing. Use additional mounting screws and wall anchors, if necessary. 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

35
CAUTION:
Secure vent hood. Make sure mounting
screws are secured into framing. Use additional
mounting screws and wall anchors, if necessary.
Remove electrical box cover.
Flip hood over. Insert 6” of electrical wiring through the
top of vent hood and secure. Refer to local codes.
Attach with screws and lock washers provided.
Attach with screws.
WARNING
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
34
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
Installation
(VWH 10”H. Wall Hoods w/Recirculating Kit)
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Duct Cover Option
(VWH 10”H. Wall Hoods w/Standard Ventilator)
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.