Viking VBCV36381 Installation Instructions - Page 5

Clearance Dimensions

Page 5 highlights

Dimensions & Specifications (VWH 18"H. 24" Deep Wall Hoods 30", 36", 42", 48", 54", & 60") (VWH 18"H. 27" Deep Wall Hoods 36", 48", & 60") Clearance Dimensions (VWH 18"H. Wall Hoods) NOTE: Optional duct cover sold separately. VWH 18"H. Wall Hoods Description 30" 36" 42" 48" Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps 29-7/8" (75.9 cm) 2 2 1 VINV300/ 600/1200 DEV900/ 1200* DIL900/1200 7"/10" (17.8/25.4 cm) 4.9/5.9 8.7/6.0 6.0/7.9 35-7/8" (91.1 cm) 2 2 1 VINV300/ 600/1200 DEV900/ 1200* DIL900/1200 7"/10" (17.8/25.4 cm) 4.9/5.9 8.7/6.0 6.0/7.9 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) 12" (30.5 cm) 12" (30.5 cm) 2 3 2 3 1 2 VINV600/ 1200 DEV900/ 1200* DIL900/1200 VINV1200* DEV1200*/ 1500** DIL1200 7"/10" (17.8/25.4 cm) 10" (25.4 cm) 10" (25.4 cm) 11.5 8.7/6.0 11.5 8.5/9.2 6.0/7.9 10.3 54" 53-7/8" (136.8 cm) 3 3 2 VINV1200* DEV1200*/ 1500** DIL1200 10" (25.4 cm) 11.5 8.5/9.2 10.3 60" 59-7/8" (152.1 cm) 4 4 2 VINV1200* DEV1200*/ 1500** DIL1200 10" (25.4 cm) 11.5 8.9/9.2 10.7 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods. 8 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

9
Dimensions & Specifications
8
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)
(VWH 18”H. 27” Deep Wall Hoods 36”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE:
Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
Clearance Dimensions
(VWH 18”H. Wall Hoods)
NOTE:
Optional duct cover sold separately.
VWH 18”H. Wall Hoods
Description
30”
36”
42”
48”
54”
60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
53-7/8”
(136.8 cm)
59-7/8”
(152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2
2
2
3
3
4
Number of filters
2
2
2
3
3
4
Heat lamps
1
1
1
2
2
2
Interior ventilator kits
VINV300/
600/1200
VINV300/
600/1200
VINV600/
1200
VINV1200*
VINV1200*
VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL900/1200
DIL900/1200
DIL900/1200
DIL1200
DIL1200
DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.9/5.9
4.9/5.9
11.5
11.5
11.5
11.5
Exterior—Maximum amps
8.7/6.0
8.7/6.0
8.7/6.0
8.5/9.2
8.5/9.2
8.9/9.2
In-Line—Maximum amps
6.0/7.9
6.0/7.9
6.0/7.9
10.3
10.3
10.7