Viking VCWB301R Installation Instructions - Page 16

Door Stop/Hinge Adjustment, Performance Checklist

Page 16 highlights

Door Stop/Hinge Adjustment DOOR STOP 1. Using a 3/16" Allen wrench, remove door stop pin located in bottom hinge. 2. The pin is factory set 110°. For 120° swing, move the pin to the utmost forward stop hole. For 90° swing, move the pin to the utmost rear stop hole. HINGE ADJUSTMENT 1. Using a 3/16" Allen wrench, remove the door stop pin located in bottom hinge. 2. Using the height adjustment shim as a wrenching device, rotate the height adjustment bushing counterclockwise to raise or clockwise to lower the location of the door. 3. When proper adjustment is reached, align shim with door stop pin holes and replace door stop pin. Firmly tighten pin in place. Performance Checklist • Verify cabinet size. • Verify electrical supply and water supply (if applicable). • Install anti-tip device(s) and verify unit is secure. • Position unit in cutout, level at desired height and secure unit. • Plug-in unit and verify operation. • Align/square door(s). • Install kickplate. • Remove internal packaging and labels and wipe unit down. Installer's information: Installer's name Installer's company Date 120˚ stop (closest to unit) 90˚ stop (farthest from unit) 30 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

31
30
Door Stop/Hinge Adjustment
DOOR STOP
1. Using a 3/16” Allen wrench, remove door stop pin located in bottom hinge.
2. The pin is factory set 110°. For 120° swing, move the pin to the utmost forward stop hole.
For 90° swing, move the pin to the utmost rear stop hole.
HINGE ADJUSTMENT
1. Using a 3/16” Allen wrench, remove the door stop pin located in bottom hinge.
2. Using the height adjustment shim as a wrenching device, rotate the height adjustment
bushing counterclockwise to raise or clockwise to lower the location of the door.
3. When proper adjustment is reached, align shim with door stop pin holes and replace door
stop pin. Firmly tighten pin in place.
90˚ stop
(farthest from unit)
120˚ stop
(closest to unit)
Performance Checklist
• Verify cabinet size.
• Verify electrical supply and water supply
(if applicable).
• Install anti-tip device(s) and verify unit is
secure.
• Position unit in cutout, level at desired
height and secure unit.
• Plug-in unit and verify operation.
• Align/square door(s).
• Install kickplate.
• Remove internal packaging and labels and
wipe unit down.
Installer’s information:
Installer’s name:
___________________________
Installer’s company:
_______________________
Date:
_____________________________________