Viking VDB450SS Installation Instructions - Page 9
Counter Balance Spring Adjustment - If Necessary, Installation Procedure - model
View all Viking VDB450SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
Counter Balance Spring Adjustment - If Necessary a b Increase tension 1 2 Decrease tension Disconnect cable from hook. c Reconnect cable to hook. Set counter balance spring connector in appropriate location. NOTE: For custom panel installation, the door may require adjustment to the preload of the counterbalance springs. Follow these steps to adjust the tension. 16 Installation Procedure 1 1b 1 Carefully lay dishwasher on its back and attach the kick plate brackets. Screws for the brackets will already be in the base. NOTE: Be careful not to pinch hoses or power cord beneath dishwasher. 2 To adjust the depth of the kick plate, loosen screws on the bracket and position in the required depth. Tighten screws and repeat for other side. 3 Using tie strap attached to dishwasher, band water line, drain line, and power cord together. 4 Position unit in front of cutout. 5a Equal distance Slide unit into opening; be sure to feed water, electrical and discharge lines into adjacent cabinet. Up Down Using a level, adjust to appropriate height. Left and right adjust side to side and center adjusts front to back. (Select models only) 17