Viking VIRT Installation Instructions - Page 10

Electrical Requirements

Page 10 highlights

Electrical Requirements Electrical Requirements Check your local codes regarding this unit. This rangetop requires 3-wire, A.C. 240 volt, 60 HZ electrical system. It must be be fused separately. Refer to the specifications chart for kilowatt rating and recommended amperage. House wiring and fusing must comply with local codes. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition. Electrical Connection When making the wire connections, use the entire length of the conduit provided (4 feet). The conduit must not be cut. Connect the red and black leads from the unit conduit to the corresponding leads in the junction box. The bare ground wire in the conduit is connected to the unit frame. When connecting to a 3-conductor branch circuit, connect the bare ground connector lead of the unit to the branch circuit ground (bare wire or green in color). WARNING The electrical power to the unit must be shut off while line connections are being made. Failure to do so could result in serious injury or death. CAUTION Be sure the electric power is off from the breaker box to the junction box until the rangetop is installed and ready to operate. The junction box should be connected to a suitable ground. WARNING FIRE AND ELECTRICAL SHOCK HAZARD DO NOT use an extension cord with this appliance. Such use may result in fire, electrical shock, or other personal injury. Cutout for electrical 5" (12.7 cm) 2" (5 cm) 3/4" (1.9 cm) minimum Electrical connection in this area 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

10
Electrical Requirements
Electrical Requirements
Check your local codes regarding this unit. This
rangetop requires 3-wire, A.C. 240 volt, 60 HZ
electrical system. It must be be fused separately.
Refer to the specifications chart for kilowatt
rating and recommended amperage. House
wiring and fusing must comply with local
codes. If no local codes are applicable, wire in
accordance with the National Electrical Code,
ANSI/NFPA 70-latest edition.
Electrical Connection
When making the wire connections, use
the entire length of the conduit provided
(4 feet). The conduit must not be cut. Connect
the red and black leads from the unit conduit to
the corresponding leads in the junction box. The
bare ground wire in the conduit is connected
to the unit frame. When connecting to a
3-conductor branch circuit, connect the bare
ground connector lead of the unit to the branch
circuit ground (bare wire or green in color).
WARNING
The electrical power to the
unit must be shut o
while line
connections are being made.
Failure to do so could result in serious
injury or death.
WARNING
FIRE AND ELECTRICAL
SHOCK HAZARD
DO NOT
use an extension
cord with this appliance. Such
use may result in
re, electrical
shock, or other personal injury.
CAUTION
Be sure the electric power is
o
from the breaker box to the
junction box until the rangetop
is installed and ready to operate. The
junction box should be connected to a
suitable ground.
Electrical
connection
in this area
3/4”
(1.9 cm)
minimum
Cutout for electrical
5”
(12.7 cm)
2”
(5 cm)