Viper 791XV Owner Manual - Page 39

disarming diagnostics

Page 39 highlights

after that input ceases, the security system will resume normal monitoring. For example, if your vehicle has an interior light exit delay and you arm your security system before the interior light turns off, you may hear a second Bypass Notification chirp. Once the light turns off, however, the security system resumes normal monitoring. note: Bypass Notification does not occur when the system is in Silent Mode or if the notification chirps have been programmed off by the installer. ➜ disarming diagnostics Extra chirps that are heard when disarming the system are the Tamper Alert. If four chirps are heard when disarming the system, then the security system was triggered in your absence. If five chirps are heard when disarming the system, a zone was triggered so many times that the Nuisance Protection Circuitry™ has bypassed that zone. In either case, the status LED will indicate which zone was involved (see Table of Zones section). The security system will retain this information in its memory and chirp four or five times each time it is disarmed, until the next time that the ignition is turned on. 36 © 2005 directed electronics-all rights reserved

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57

36
© 2005 directed electronics—all rights reserved
after that input ceases, the security system will resume normal
monitoring. For example, if your vehicle has an interior light exit
delay and you arm your security system before the interior light
turns off, you may hear a second Bypass Notification chirp. Once
the light turns off, however, the security system resumes normal
monitoring.
disarming diagnostics
Extra chirps that are heard when disarming the system are the
Tamper Alert. If four chirps are heard when disarming the
system, then the security system was triggered in your absence. If
five chirps are heard when disarming the system, a zone was trig-
gered so many times that the Nuisance Protection Circuitry
has
bypassed that zone. In either case, the status LED will indicate
which zone was involved (see
Table of Zones
section). The secu-
rity system will retain this information in its memory and chirp
four or five times each time it is disarmed, until the next time
that the ignition is turned on.
note:
Bypass Notification does not occur when the sys-
tem is in Silent Mode or if the notification chirps have
been programmed off by the installer.