Waring MX1000RXT Instruction Booklet - Page 4

Important

Page 4 highlights

CLEANING AND SANITIZING INSTRUCTIONS THE CONTAINER MUST BE CLEANED AND DRIED AFTER EACH USE OF THE BLENDER ACCORDING TO THE FOLLOWING INSTRUCTIONS. FAILURE TO DO SO MAY ALLOW RESIDUES OF PROCESSED MATERIAL TO COLLECT ON THE INTERNAL SEALS OF THE BLADE ASSEMBLY, RENDERING THEM INEFFECTIVE. • Wash, rinse, sanitize and dry container prior to initial use and whenever it will not be used again within a period of 1 hour. • Wash and rinse container after each use. • Clean and sanitize motor base prior to initial use and after each use. • Washing solutions based on non-sudsing detergents and chlorine-based sanitizing solutions having a minimum chlorine concentration of 100 PPM are recommended. The following washing, rinsing, and sanitizing solutions, or their equivalents, may be used. SOLUTION PRODUCT DILUTION IN WATER TEMPERATURE Washing Diversy Wyandotte *Diversol® BX/a or CX/A 4 Tablespoons /Gallon Hot 115˚F ( 46˚C ) Rinsing Plain Water Warm 95˚F (35˚C) Sanitizing **Clorox® 1 Tablespoon/Gallon Institutional Bleach Cold 50-70˚F ( 10-21˚C) *Diversol® is a registered trademark owned by the Diversey Wyandotte Corp. **Clorox® is a registered trademark owned by the Clorox Company. • In repetitive batch-processing applications, frequent cleaning of the container will prolong the life of the blade assembly. In no case should actual running time between cleanings exceed ½ hour. • Do not use container to store processed foods or beverages. To wash and rinse container: 1. REMOVE CONTAINER FROM MOTOR BASE. Remove lid. Rinse container interior and lid under running water. Add washing solution to container. Scrub and flush out the container interior and lid to dislodge and remove as much food residue as possible. Empty container. 6 2. Wipe down exterior of container with a soft cloth or sponge dampened with washing solution. Wash lid and lid insert in fresh washing solution. Fill container ¼ full with fresh washing solution, cover (with lid only but without center piece), place on motor base and run on HI for two (2) minutes. Empty container. 3. Repeat step (2) using clean rinse water in place of washing solution. IMPORTANT NOTE: IN ORDER TO MINIMIZE POSSIBILITY OF SCALDING, TEMPERATURE OF WASHING SOLUTION AND RINSE WATER MUST NOT EXCEED 115˚F (46˚C), AND QUANTITY USED MUST NOT EXCEED ¼-CONTAINER FULL. IF HIGHER TEMPERATURES OR LARGER QUANTITIES ARE USED, OBSERVE ALL PRECAUTIONS GIVEN IN THE OPERATING MANUAL UNDER "HOT BLENDING INSTRUCTIONS." To sanitize and dry container: 1. Wipe down exterior of container with a soft cloth or sponge dampened with sanitizing solution. 2. Fill container with sanitizing solution, cover, place on motor base, and run on high speed for two (2) minutes. Empty container. Dislodge any residual moisture from blade assembly by placing empty container on motor base and running on high speed for two (2) seconds. 3. Sanitize lid and lid insert by immersing in sanitizing solution for two (2) minutes. 4. Do not rinse container, lid, or lid insert after sanitizing is completed. Allow parts to air-dry. To clean and sanitize motor base: 1. UNPLUG POWER CORD. Wipe down exterior surfaces of motor base with soft cloths or sponges dampened with washing solution, rinse water, and sanitizing solution. Prevent liquid from running into motor base by wringing all excess moisture from cloths or sponges before using them. DO NOT IMMERSE MOTOR BASE IN WASHING SOLUTION, RINSE WATER OR SANITIZING SOLUTION. 2. Allow motor base to air-dry before using. Any other servicing should be performed by an authorized service representative. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

6
7
CLEANING AND SANITIZING INSTRUCTIONS
THE CONTAINER MUST BE CLEANED AND DRIED AFTER EACH
USE OF THE BLENDER ACCORDING TO THE FOLLOWING
INSTRUCTIONS. FAILURE TO DO SO MAY ALLOW RESIDUES OF
PROCESSED MATERIAL TO COLLECT ON THE INTERNAL SEALS
OF THE BLADE ASSEMBLY, RENDERING THEM INEFFECTIVE.
Wash, rinse, sanitize and dry container prior to initial use and
whenever it will not be used again within a period of 1 hour.
• Wash and rinse container after each use.
Clean and sanitize motor base prior to initial use and after
each use.
Washing solutions based on non-sudsing detergents and
chlorine-based sanitizing solutions having a minimum chlorine
concentration of 100 PPM are recommended.
The following washing, rinsing, and sanitizing solutions, or their
equivalents, may be used.
SOLUTION
PRODUCT
DILUTION IN WATER
TEMPERATURE
Washing
Diversy Wyandotte
4 Tablespoons
Hot 115˚F ( 46˚C )
*Diversol® BX/a or CX/A
/Gallon
Rinsing
Plain Water
Warm 95˚F (35˚C)
Sanitizing
**Clorox®
1 Tablespoon/Gallon
Cold 50-70˚F
Institutional Bleach
( 10-21˚C)
*Diversol
®
is a registered trademark owned by the Diversey Wyandotte Corp.
**Clorox
®
is a registered trademark owned by the Clorox Company.
In repetitive batch-processing applications, frequent cleaning
of the container will prolong the life of the blade assembly.
In no case should actual running time between cleanings
exceed ½ hour.
• Do not use container to store processed foods or beverages.
To wash and rinse container:
1.
REMOVE CONTAINER FROM MOTOR BASE. Remove lid.
Rinse container interior and lid under running water.
Add
washing solution to container. Scrub and flush out the
container interior and lid to dislodge and remove as much
food residue as possible. Empty container.
IMPORTANT
NOTE: IN ORDER TO MINIMIZE POSSIBILITY OF SCALDING,
TEMPERATURE OF WASHING SOLUTION AND RINSE WATER
MUST NOT EXCEED 115˚F (46˚C), AND QUANTITY USED MUST
NOT EXCEED ¼-CONTAINER FULL.
IF HIGHER TEMPERATURES OR LARGER QUANTITIES ARE
USED, OBSERVE ALL PRECAUTIONS GIVEN IN THE OPERATING
MANUAL UNDER “HOT BLENDING INSTRUCTIONS.”
To sanitize and dry container:
1.
Wipe down exterior of container with a soft cloth or sponge
dampened with sanitizing solution.
2.
Fill container with sanitizing solution, cover, place on motor
base, and run on high speed for two (2) minutes.
Empty
container. Dislodge any residual moisture from blade assembly
by placing empty container on motor base and running on high
speed for two (2) seconds.
3.
Sanitize lid and lid insert by immersing in sanitizing solution for
two (2) minutes.
4.
Do not rinse container, lid, or lid insert after sanitizing is
completed. Allow parts to air-dry.
To clean and sanitize motor base:
1.
UNPLUG POWER CORD. Wipe down exterior surfaces of
motor base with soft cloths or sponges dampened with
washing solution, rinse water, and sanitizing solution. Prevent
liquid from running into motor base by wringing all excess
moisture from cloths or sponges before using them.
DO NOT IMMERSE MOTOR BASE IN WASHING SOLUTION, RINSE
WATER OR SANITIZING SOLUTION.
2.
Allow motor base to air-dry before using.
Any other servicing should be performed by an authorized service
representative.
2.
Wipe down exterior of container with a soft cloth or sponge
dampened with washing solution. Wash lid and lid insert in
fresh washing solution. Fill container ¼ full with fresh washing
solution, cover (with lid only but without center piece), place on
motor base and run on HI for two (2) minutes. Empty container.
3.
Repeat step (2) using clean rinse water in place of washing
solution.